Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc. <br /> Auer Steel(New Hope) Midwest Custom Const. <br /> Plymouth,MN 55441 F1 Page 6 <br /> System 1 Summary Loads <br /> Component Area Sen Lat Sen Total <br /> Description Quan Loss Gain Gain Gain <br /> 2A-v-o: Glazing-Double pane low-e (e = 0.60), operable 239.8 12,132 0 14,417 14,417 <br /> window, vinyl frame, u-value 0.55, SHGC 0.61 <br /> 11 P: Door-Metal - Polyurethane Core 21 560 0 207 207 <br /> 12E-Osw: Wall-Frame, R-19 insulation in 2 x 6 stud 2007.2 12,556 0 3,467 3,467 <br /> cavity, no board insulation, siding finish, wood studs <br /> 12E-Osw: Part-Frame, R-19 insulation in 2 x 6 stud cavity, 301.5 1,435 0 205 205 <br /> no board insulation, siding finish, wood studs <br /> 16B-30: Roof/Ceiling-Under Attic with Insulation on Attic 108 318 0 200 200 <br /> Floor(also use for Knee Walls and Partition <br /> Ceilings), Vented Attic, No Radiant Barrier, Dark <br /> Asphalt Shingles or Dark Metal, Tar and Gravel or <br /> Membrane, R-30 insulation <br /> 16A-38: Roof/Ceiling-Under Attic with Insulation on Attic 1232 2,947 0 2,498 2,498 <br /> Floor(also use for Knee Walls and Partition <br /> Ceilings), Unvented Attic, No Radiant Barrier, Any <br /> Roofing Material, Any Roof Color, R-38 insulation <br /> 19B-s8.25p: Floor-Over enclosed unconditioned crawl 1064 1,756 0 439 439 <br /> space, R-4 insulation on exposed walls, sealed crawl <br /> space, passive, 8.25 inch R-29.77 SIP panels with R - <br /> 3.85 per inch EPS core <br /> 20P-30: Floor-Over open crawl space or garage, Passive, 288 927 0 181 181 <br /> R-30 blanket insulation, any cover <br /> Subtotals for structure: 32,631 0 21,614 21,614 <br /> People: 0 0 0 0 <br /> Equipment: 0 0 0 <br /> Lighting: 0 0 0 <br /> Ductwork: 0 0 0 0 <br /> Infiltration: Winter CFM: 104, Summer CFM: 52 10,176 1,036 1,272 2,308 <br /> Ventilation: Winter CFM: 140, Summer CFM: 140 8,248 2,798 3,093 5,891 <br /> AED Excursion: 0 0 411 411 <br /> System 1 Load Totals: 51,055 3,834 26,390 30,225 <br /> Check Figures <br /> Supply CFM: 1,091 CFM Per Square ft.: 0.475 <br /> Square ft. of Room Area: 2,296 Square ft. Per Ton: 912 <br /> Volume (ft3) of Cond. Space: 19,432 <br /> System Loads <br /> Total Heating Required Including Ventilation Air: 51,055 Btuh 51.055 MBH <br /> Total Sensible Gain: 26,390 Btuh 87 % <br /> Total Latent Gain: 3,834 Btuh 13 % <br /> Total Cooling Required Including Ventilation Air: 30,225 Btuh 2.52 Tons (Based On Sensible + Latent) <br /> Notes <br /> Rhvac is an ACCA approved Manual J and Manual D computer program. <br /> Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. <br /> All computed results are estimates as building use and weather may vary. <br /> Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at <br /> your design conditions. <br /> C:\ ...\Midwest Custom Const - Countryside Solutions.rhv Thursday, November 20, 2014, 9:36 AM <br />