Laserfiche WebLink
Rhvsc-Residential&Light Commercial HVAC Loads Elite Software Development,Inc. <br /> Auer Steel(New Hope) Midwest Custom Const <br /> Plymouth,MN 55441 __ Page 3 <br /> Miscellaneous Report <br /> System 1 Outdoor Outdoor Outdoor In Indoor Grains <br /> Ind pate Dry Bulb Wet Bulb Rel.Hum Rel.Hum Dry Bulb Difference <br /> Winter: -20 -12.38 100'/° WA72 n/a <br /> Summer: 95 73 36% 500/0 72 30.30 <br /> Duct Sizing Inputs � <br /> Main Trunk Runouts <br /> Calculate: Yes Yes <br /> Use Schedule: Yes Yes <br /> Roughness Factor: 0.00300 0.01000 <br /> Pressure Drop: 0.1000 in.wg./100 ft. 0.1000 in.wg./100 ft. <br /> Minimum Velocity: 650 ft./min 450 ft./min <br /> Maximum Velocity: 900 ft./min 750 ftJmin <br /> Minimum Height: 0 in. 0 in. <br /> Maximum Height: 0 in. 0 in. <br /> Out_s_i_d_e Air Data <br /> Winter Summer <br /> Infiltration Specified: 0.320 AC/hr 0.160 AC/hr <br /> 104 CFM 52 CFM <br /> Infiltration Actual: 0.320 AC/hr 0.160 AC/hr <br /> Above Grade Volume: X 19.432 Cu.ft. X 19.432 Cu.ft. <br /> 6,218 Cu.ft./hr 3,109 Cu.ft./hr <br /> X 0.0167 X 0.0167 <br /> Total Building Infiltration: 104 CFM 52 CFM <br /> Total Building Ventilation: 140 CFM 140 CFM <br /> ---System 1--- <br /> Infiltration&Ventilation Sensible Gain Multiplier: 24.55 = (1.10 X 0.970 X 23.00 Summer Temp. Difference) <br /> Infiltration&Ventilation Latent Gain Multiplier: 19.99 = (0.68 X 0.970 X 30.30 Grains Difference) <br /> Infiltration&Ventilation Sensible Loss Multiplier: 98.19 = (1.10 X 0.970 X 92.00 Winter Temp. Difference) <br /> Winter Infiltration Specified: 0.320 AC/hr(104 CFM), Construction: Average <br /> Summer Infiltration Specified: 0.160 AC/hr(52 CFM), Construction:Average <br /> C:1 ...\Midwest Custom Const-Countryside Solutions.rhv Thursday, November 20,2014, 9:36 AM <br />