My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2014-01358 - new structutre
Orono
>
Property Files
>
Street Address
>
N
>
North Shore Drive
>
4680 North Shore Drive - 07-117-23-32-0050
>
Permits/Inspections
>
2014-01358 - new structutre
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 5:35:40 PM
Creation date
1/30/2018 12:38:08 PM
Metadata
Fields
Template:
x Address Old
House Number
4680
Street Name
North Shore
Street Type
Drive
Address
4680 North Shore Dr
Document Type
Permits/Inspections
PIN
0711723320050
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
70
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc. <br /> Auer Steel(New Hope) Midwest Custom Const. <br /> Plymouth.MN 55441 In Page 2 <br /> Project Report <br /> General Project Information <br /> Project Title: Midwest Custom Const. <br /> Project Date: Thursday, November 20, 2014 <br /> Company Name: Countryside Solutions <br /> Design Data <br /> Reference City: Minneapolis, Minnesota <br /> Building Orientation: Front door faces West <br /> Daily Temperature Range: Medium <br /> Latitude: 44 Degrees <br /> Elevation: 834 ft. <br /> Altitude Factor: 0.970 <br /> Elevation Sensible Adj. Factor: 1.000 <br /> Elevation Total Adj. Factor: 1.000 <br /> Elevation Heating Adj. Factor: 1.000 <br /> Elevation Heating Adj. Factor: 1.000 <br /> Outdoor Outdoor Outdoor Indoor Indoor Grains <br /> Dry Bulb Wet Bulb Rel.Hum Rel.Hum Dry Bulb Difference <br /> Winter: -20 -12.38 100% n/a 72 n/a <br /> Summer: 95 73 36% 50% 72 30 <br /> Check Figures <br /> Total Building Supply CFM: 1,091 CFM Per Square ft.: 0.475 <br /> Square ft. of Room Area: 2,296 Square ft. Per Ton: 912 <br /> Volume (W) of Cond. Space: 19,432 <br /> Building Loads <br /> Total Heating Required Including Ventilation Air: 51,055 Btuh 51.055 MBH <br /> Total Sensible Gain: 26,390 Btuh 87 % <br /> Total Latent Gain: 3,834 Btuh 13 % <br /> Total Cooling Required Including Ventilation Air: 30,225 Btuh 2.52 Tons (Based On Sensible+ Latent) <br /> Notes <br /> Rhvac is an ACCA approved Manual J and Manual D computer program. <br /> Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. <br /> All computed results are estimates as building use and weather may vary. <br /> Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at <br /> your design conditions. <br /> C:\ ...\Midwest Custom Const- Countryside Solutions.rhv Thursday, November 20, 2014, 9:36 AM <br />