Laserfiche WebLink
Rhvac-Residential&Light Commercial HVAC LoadsElite Software Development,Inc. <br /> Rigger Heating and Cooling Wooddale 765 Boulder Dr. Revised <br /> Andover, MN 55304 Page 2 <br /> Total Building Summary Loads <br /> Component Area Sen Lat Sen Total <br /> I Description Quan Loss Gain Gain Gain <br /> 4A-6-d: Glazing-Double pane low-e (e= 0.20 or less), 88.8 2,490 0 936 936 <br /> high performance, sliding glass door, e=0.05 on <br /> surface 2, any frame, u-value 0.33, SHGC 0.33 <br /> Andersen: Glazing-operable window, wood sash, u-value 380.6 9,386 0 9,726 9,726 <br /> 0.29, SHGC 0.32 <br /> Andersen: Glazing-operable window, wood sash, outdoor 103.9 2,564 0 3,152 3,152 <br /> insect screen with 50% coverage, u-value 0.29, <br /> SHGC 0.32 <br /> 11N: Door-Metal - Polystyrene Core 48 1,428 0 404 404 <br /> 12F-Osw: Wall-Frame, R-21 insulation in 2 x 6 stud 1857.3 10,262 0 1,607 1,607 <br /> cavity, no board insulation, siding finish, wood studs <br /> 15B0-10sf-8: Wall-Basement, , R-10 board insulation to 480.1 2,346 0 85 85 <br /> floor, no interior finish, 8'floor depth <br /> 15B0-8sf-8: Wall-Basement, , R-8 board insulation to 399 2,257 0 96 96 <br /> floor, no interior finish, 8'floor depth <br /> 15B0-10sf-4: Wall-Basement, , R-10 board insulation to 162.8 747 0 0 0 <br /> floor, no interior finish, 4'floor depth <br /> 16B-50: Roof/Ceiling-Under Attic with Insulation on Attic 1921 3,266 0 1,844 1,844 <br /> Floor(also use for Knee Walls and Partition <br /> Ceilings), Vented Attic, No Radiant Barrier, Dark <br /> Asphalt Shingles or Dark Metal, Tar and Gravel or <br /> Membrane, R-50 insulation <br /> 21A-32: Floor-Basement, Concrete slab, any thickness, 2 1737 2,953 0 0 0 <br /> or more feet below grade, no insulation below floor, <br /> any floor cover, shortest side of floor slab is 32'wide <br /> 20P-30: Floor-Over open crawl space or garage, Passive, 184 547 0 52 52 <br /> R-30 blanket insulation, any cover <br /> Subtotals for structure: 38,246 0 17,902 17,902 <br /> People: 5 1,000 1,150 2,150 <br /> Equipment: 722 7,070 7,792 <br /> Lighting: 0 0 0 <br /> Ductwork: 0 0 0 0 <br /> Infiltration: Winter CFM: 45, Summer CFM: 22 4,071 348 312 660 <br /> Ventilation: Winter CFM: 133, Summer CFM: 133 4,826 2,063 738 2,801 <br /> Exhaust: Winter CFM: 133, Summer CFM: 133 <br /> Humidification (Winter) 8.17 gal/day : 2,995 0 0 0 <br /> AED Excursion: 0 0 2,569 2,569 <br /> Total Building Load Totals: 50,138 4,133 29,741 33,874 <br /> Check Figures <br /> Total Building Supply CFM: 1,359 CFM Per Square ft.: 0.371 <br /> Square ft. of Room Area: 3,658 <br /> Volume (ft3): 26,924 <br /> Building Loads <br /> Total Heating Required Including Ventilation Air: 50,138 Btuh 50.138 MBH <br /> Total Sensible Gain: 29,741 Btuh 88 ok <br /> Total Latent Gain: 4,133 Btuh 12 % <br /> Total Cooling Required Including Ventilation Air: 33,874 Btuh <br /> Notes <br /> Rhvac is an ACCA approved Manual J and Manual D computer program. <br /> Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. <br /> All computed results are estimates as building use and weather may vary. <br /> Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at <br /> your design conditions. <br /> C:\...\Wooddale 765 Boulder Dr. Revised .rh9 Thursday, December 21, 2017, 10:16 AM <br />