2017-01665 - new structure
Orono
>
Property Files
>
Street Address
>
B
>
Boulder Drive
>
765 Boulder Drive - PID: 33-118-23-11-0134 - New PID
>
Permits/Insepctions
>
2017-01665 - new structure
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:45:09 PM
Creation date
1/29/2018 3:31:19 PM
Metadata
Fields
Template:
x Address Old
House Number
765
Street Name
Boulder
Street Type
Drive
Address
765 Boulder Drive
PIN
3311823110134
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
32
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc. <br /> •Riccar Heating and Cooling Wooddale 765 Boulder Dr. Revised <br /> Andover,MN 55304 Page 1 <br /> Project Report <br /> General Project Information <br /> Project Title: Wooddale 765 Boulder Dr. Revised <br /> Designed By: Kurt <br /> Project Date: 12/21/17 <br /> Project Comment: 765 Boulder Dr., Orono, MN <br /> Client Name: Wooddale Builders <br /> Company Name: Riccar Heating And Air <br /> Company Representative: Kurt <br /> Company Address: 2387 Station Parkway NW <br /> Company City: Andover, MN 55304 <br /> Company Phone: 763-754-4000 <br /> Company Fax: 763-754-0132 <br /> Company E-Mail Address: Kurt@riccarhvac.com <br /> Company Website: riccarhvac.com <br /> Design Data <br /> Reference City: Minneapolis/St. Paul AP, Minnesota <br /> Building Orientation: Front door faces East <br /> Daily Temperature Range: Medium <br /> Latitude: 44 Degrees <br /> Elevation: 834 ft. <br /> Altitude Factor: 0.970 <br /> Outdoor Outdoor Outdoor Indoor Indoor Grains <br /> Dry Bulb Wet Bulb Rel.Hum Rel.Hum Dry Bulb Difference <br /> Winter: -15 -11.42 n/a 30% 70 25.53 <br /> Summer: 88 71 44% 50% 75 24 <br /> I Check Figures • <br /> Total Building Supply CFM: 1,359 CFM Per Square ft.: 0.371 <br /> Square ft. of Room Area: 3,658 <br /> Volume(ft'): 26,924 <br /> Building Loads <br /> Total Heating Required Including Ventilation Air: 50,138 Btuh 50.138 MBH <br /> Total Sensible Gain: 29,741 Btuh 88 % <br /> Total Latent Gain: 4,133 Btuh 12 % <br /> Total Cooling Required Including Ventilation Air: 33,874 Btuh <br /> Notes <br /> Rhvac is an ACCA approved Manual J and Manual D computer program. <br /> Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. <br /> All computed results are estimates as building use and weather may vary. <br /> Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at <br /> your design conditions. <br /> C:\...\Wooddale 765 Boulder Dr. Revised .rh9 Thursday, December 21, 2017, 10:16 AM <br />