My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2017-01589 - new septic
Orono
>
Property Files
>
Street Address
>
F
>
Fox Street
>
1840 Fox Street - 03-117-23-42-0008
>
Septic
>
2017-01589 - new septic
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:38:06 PM
Creation date
1/22/2018 3:35:36 PM
Metadata
Fields
Template:
x Address Old
House Number
1840
Street Name
Fox
Street Type
Street
Address
1840 Fox St
Document Type
Septic
PIN
0311723420008
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
18
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
INSPECTOR CHECKLIST - mound <br /> 1641U Iox street <br /> EiWELL setbacks: 20'to pressure tested sewer line (5 psi for 15 min) <br /> -1 50'to everything 100'to dispersal area with shallow well <br /> f PROPERTY LINES setback: 10'to everything <br /> -1 Road setback: platted: 10'prop line. Metes ft bounds: out of road easement, or outer ditch. <br /> LAKE BEI"FT setback: 20'for bluff, Lakes: GD , RD_, NE . Protected Protected wetland_. <br /> Building setbacks: 10'for everything, 20'for dispersal area. <br /> .d WA FER LINE under pressure sl 10'to bed,tank Et sewer line. (else sewer line > 12"below) <br /> E] Sewer line Et baffle connection (no 90's, 3'between 45's, slope min 1"in 8', max 2"in 8') <br /> (no depth req's, clean out every 100', Sch 40 pipe) <br /> ESeptic tank and risers (water tight, insulated, proper depth, existing verified by pumping) <br /> mfg 2250 gallons none <br /> Riser over outlet, riser over inlet or center, and 6"+inspection pipe over any remaining baffles. <br /> No effluent fitter&alarm <br /> — <br /> Dose tank risers and piping (water tight, insulated, proper depth, drainback) <br /> — <br /> mfg 1300 gallons <br /> L_ dose pump 29 gpm 25 head VERIFY PUMP CURVE 5.9 min ON 9 hr OFF <br /> El float setting drop 6.7 inches at 25.5 gpi "DESIGNED" 4,4 inches approx float tether length <br /> 171.0 gal dose divided by gpi "INSTALLED" = inches float drop(field corrected <br /> LABEL pump requirements and drawdown on riser or panel <br /> Cam lock reachable from grade- 30"max. J-hook weep hole. Supply line access (no hard 90's) <br /> 2.0 inch supply pipe: Sch40, sloped 1/8"+, supported by 4"sch40 sleeve or compacted, and buried 6"+. <br /> splice box / control panel /electrical connections <br /> flow measurement: CT, ETM, time dosed, home water meter <br /> mound absorption area rough up <br /> mound rock dimensions 10.0 X 50.0 <br /> Sand lift depth 12 inches. (Jar test: 2"sand leaves < 1/8"silt after 30 min) <br /> ElAbsorption Sand beyond rock 0.0 upstope 10.0 downslope <br /> Bermed topsoil beyond rockbed 10 upslope 12 sideslope 20 downslope <br /> cover depth of 12-18"+ VERIFY <br /> 3 laterals (1-2'from edge of rock) <br /> 2.00 inch pipe size (Sch40 pipe a fittings) <br /> 3.0 ft lateral spacing <br /> 7 7/32 inch perforations <br /> 3.0 ft perforation spacing <br /> Air inlet at end of laterals, and at top feed manifold if necessary. VERIFY <br /> clean outs (no hard 90's) <br /> 4"inspection pipe to bottom of rock, anchored VERIFY <br /> (— Abandon existingsystem -if necessary y Re•use existing tank certification <br /> monitoring plan and type <br /> well abandonment form - if necessary <br />
The URL can be used to link to this page
Your browser does not support the video tag.