My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2017-01589 - new septic
Orono
>
Property Files
>
Street Address
>
F
>
Fox Street
>
1840 Fox Street - 03-117-23-42-0008
>
Septic
>
2017-01589 - new septic
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:38:06 PM
Creation date
1/22/2018 3:35:36 PM
Metadata
Fields
Template:
x Address Old
House Number
1840
Street Name
Fox
Street Type
Street
Address
1840 Fox St
Document Type
Septic
PIN
0311723420008
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
18
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Installer Summary <br /> 2250 gallon Septic tank (minimum) Tank options: none <br /> U b wiser Lana wun rnutupie comp/t.an$S <br /> 1300 gallon Dose tank (minimum) at 25.49 gpi <br /> 29 GPM 0 25 ft. of head, Pump required <br /> 6.7 inch swing on Demand float which translates to roughly 4.4 inches of float tether length <br /> if time dosing is required --> 5.9 minutes ON time Ft 9 hours OFF time <br /> 19 inches from bottom of tank to"pump ON"float, or 12 inches to"timer ON"float <br /> 22 inches from bottom of tank to"Hi Level Alarm"or 32 inches to"Hi level alarm"if time dosed <br /> 122 ft. of 2.0 ,inch supply line with end feed manifold connection <br /> (Tip: "top feed"manifold to control drainback) <br /> 12 inch, or 1.0 ft. Sand Lift Mound <br /> 10.0 ft. wide by 50.0 ft. long Rock bed <br /> 3 laterals 2.00 inch diameter 48.0 ft. long 3.0 ft. lateral spacing <br /> 7/32 inch perfs 3.0 ft. perforation spacing <br /> No Effluent filter&alarm <br /> 3 clean out&varve box assemblies <br /> 20.0 ft.Total sand ABSORPTION width (minimum) <br /> 0.0 ft. upslope and sideslope (sand beyond rockbed, minimum) <br /> 10.0 ft. Downslope <br /> Specific slope ratios give BERM widths (topsoil beyond rockbed)of: <br /> 4:1 upslope ratio 10 ft. upslope berm <br /> 3:1 sideslope 12 ft. sideslope berms <br /> 4:1 downslope 20 ft. downslope berm <br /> 4' inspection pipe <br /> 18" cover on top <br /> Upslope berm 10 Downslo•e berm 20 <br /> 001 <br /> annum- 12" cover on sides <br /> r _._` �____ ________ _ (6"loamy cap&6"topsoil) <br /> 1.0 iE'ziti SGtiCi flit "�•�.`^ <br /> 2.2 <br /> Absorption Width 20.0 <br /> Note: II" <br /> For 0 to 1%slopes, Absorption Width is measured from the Bedequally in both directions. <br /> For slopes >1%. Absorption Width is measured downhill from the upslope edge of the Bed. <br /> Rock Bed: 17.0 yd3 or*1.4= 24 ton 6 inches under pipe <br /> Mound Sana: 127 yd3 or"1.4= 178 ton calculation based on 3:1/4:1 slope from top of rockbei <br /> Loamy Cap: 56 yd3 or"1.4= 78 ton 6"deep <br /> Topsoil: 66 lyd3 or*1.4= 92 ton 6"deep <br />
The URL can be used to link to this page
Your browser does not support the video tag.