2017-00492 - ROW permit
Orono
>
Property Files
>
Street Address
>
D
>
Dickey Lake Drive
>
701 Dickey Lake Drive - 34-118-23-22-0005
>
Permits/Inspections
>
2017-00492 - ROW permit
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:56:04 PM
Creation date
1/19/2018 12:19:50 PM
Metadata
Fields
Template:
x Address Old
House Number
701
Street Name
Dickey Lake
Street Type
Drive
Address
701 Dickey Lake Drive
Document Type
Permits/Inspections
PIN
3411823220005
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
58
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
14. SITE DRAINAGE <br /> 14.1 The CONTRACTOR shall be required to provide for drainage throughout the site during <br /> his construction operations. The CONTRACTOR shall leave the site at the end of each <br /> construction day in such condition that in the event of rain there will be no water ponded within <br /> the building pads and/or street areas of the site. <br /> 14.2 The CONTRACTOR shall be required to maintain the site in such a condition that no <br /> water ponds within the street area for a period of time exceeding 24 hours. In the event that <br /> water is ponding within the street areas for a period of time longer than 24 hours the <br /> CONTRACTOR shall be penalized a sum of $500.00 per day that water is ponding beyond the <br /> initial 24 hour period. This penalty shall be applied to each individual area of the site where <br /> ponding is evident. This money shall be deducted from monies due the CONTRACTOR for <br /> work previously completed and shall be used to offset extra costs incurred by the OWNER for <br /> street subgrade correction work due to soft subgrades. <br /> 15. SANITARY SEWER <br /> 15.1 All sanitary sewer shall be constructed in accordance with the City of Orono Standard <br /> Details. <br /> 15.2 The pipe used for Sanitary Sewer Mainlines and service lines deeper than 26 feet below <br /> finished centerline shall be ductile iron pipe, as specified in the Standard Sewer Construction <br /> Specifications. The pipe used for Sanitary Sewer Mainlines and service lines between 15 and <br /> 26 feet deep shall be polyvinyl chloride SDR 26. The pipe used for Sanitary Sewer Mainlines <br /> and services lines less than 15 feet deep shall be polyvinyl chloride SDR 35 as specified in the <br /> Standard Sewer Construction Specifications, unless otherwise noted on the Construction Plans. <br /> 15.3 The CONTRACTOR shall be paid at the Bid Price for Trench Stabilization Rock for the <br /> actual amount of rock used as ordered by the ENGINEER. The quantity listed in the Proposal is <br /> approximate; the ENGINEER may order the CONTRACTOR to use as little or as much rock as <br /> is required to complete the PROJECT. <br /> 15.4 The CONTRACTOR shall install the sewer services to ten (10) feet past the property <br /> line, with the tracer wire and fence post, as shown on the STANDARD DETAILS. <br /> 15.5 The CONTRACTOR shall be required to perform in accordance with the Standard Sewer <br /> Construction specifications the following tests: <br /> 1. Low Pressure Air Test <br /> 2. Deflection Test <br /> 3. Lamping of lines with City and Engineer present. <br /> 4. Television inspection of all lines. <br /> 15.6 The CONTRACTOR shall submit the original and one copy of the television inspection <br /> report to the ENGINEER. <br /> 15.7 Manhole Frames and Covers - Manhole frames and covers shall be Neenah R-1642-B <br /> with B type solid lid, or approved equal, unless otherwise noted on the Construction Plans or <br /> City of Orono Specifications. <br /> 16. WATERMAIN <br /> 16.1 All watermain shall be constructed in accordance with the City of Orono Engineering <br /> Guidelines and Standard Details. <br /> SP-6 <br />
The URL can be used to link to this page
Your browser does not support the video tag.