My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Septic Design
Orono
>
Property Files
>
Street Address
>
B
>
Bayside Trail
>
125 Bayside Trail - 06-117-23-22-0029
>
Septic
>
Septic Design
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 5:25:17 PM
Creation date
1/17/2018 10:48:19 AM
Metadata
Fields
Template:
x Address Old
House Number
125
Street Name
Bayside
Street Type
Trail
Address
125 Bayside Tr
Document Type
Septic
PIN
0611723220029
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
22
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
2011 purple code Mound Design <br /> www.SepticResource.com (vers 15.2) <br /> Property Owner: M and M Construction Date: 12/12/2017 <br /> Site Address: 125 Bayside Trail, Orono, MN 55359 PID: 0611723220029 <br /> Comments: NEW CONSTRUCTION <br /> instructions: =enter data = adjust if desired = computer calculated - DO NOT CHANGE! <br /> 5 bedroom Type I Residential System <br /> 2) 750 GPD design flow <br /> 3) No Garbage disposal or pumped to septic <br /> 4) 2250 Gal Septic tank (code minimum) 2250 Gal Septic tank (design size / LUG req'd) <br /> Tank options: Multiple tanks or compartments req'd <br /> 5) 1.2 GPD/ft2 mound sand loading rate contour loading rate of 12 req's a min 62.5 ft. long rockbed <br /> 6) 10.0 ft rockbed width 63.0 ft rockbed length <br /> 7) 3.0 ft lateral spacing 3.0 ft perforation spacing (maximum of 3 for both) <br /> end feed manifold connection <br /> 8) 3 laterals 61.0 feet long 21.0 perfs / lateral 63 perfs total <br /> (1/2 a perf means the first perf starts at the middle feed manifold) <br /> 9) 7/32 inch perfs at 1 feet residual head gives 0.56 gpm flow rate per perforation <br /> for this perf size a spacing, Et pipe size on line 12, max perfs/lateral= 30 , line#8 must be less --> OK <br /> 10) 5.0 doses per day ( 4 minimum) <br /> 11) 150 gallons per dose (treatment volume) <br /> 1.50 5x <br /> 12) 2.00 inch diameter laterals must be used to meet"4x pipe volume" requirement <br /> 2.00 3x <br /> 13) 90 feet of 2.0 inch supply line leads to 15 gallons of drainback volume <br /> (Tip: "top feed" manifold to control the drainback) <br /> 14) 165 gallons TOTAL pump out volume (treatment+ drainback) <br /> 15) 12 feet vertical lift from pump to mound laterals, leads to a: <br /> 16) 36 GPM® 21 feet of head, Pump requirement (note: >50gpm may require an extra 3-6'of head) <br /> 17) 1000 gal Dose tank (code minimum) 1500 gal Dose tank (design size / LUG req'd) at 36.80 gpi <br /> leads to a <br /> 18) 4.5 inch swing on Demand float, or timed dosing of 4.6 min ON (confirm pump rate with drawdown <br /> (this delivers Average flow, =70%of Peak design flow) 7.2 hrs OFF test and adjust as necessary) <br /> 19) 12 inches from bottom of tank to"Pump OFF"float <br /> 20) 17 inches from bottom of tank to"Pump ON"float, or 12 inches to"Timer ON"float if time dosed <br /> 21) 20 inches from bottom of tank to"Hi Level"float, or 30 inches to"Hi Level"float if time dosed <br /> 22) 764 gallons reserve capacity (after High Level Alarm is activated) <br />
The URL can be used to link to this page
Your browser does not support the video tag.