Laserfiche WebLink
Page 2 of 8 <br /> NIKING® QUICK RESPONSE <br /> TECHNICAL DATA DRY HORIZONTAL <br /> SIDEWALL SPRINKLERS <br /> The Viking Corporation,210 N Industrial Park Drive,Hastings MI 49058 <br /> Telephone:269-945-9501 Technical Services:877-384-5464 Fax:269-818-1680 Email:techsvcs@vikingcorp.com <br /> These sprinklers are listed and approved in lengths from 1-1/2'to 45-1/2"(38.1 mm to 1,156 mm)for the adjustable standard style,3"to <br /> 47"(76.2 mm to 1,194 mm)for the plain barrel style,and 3-1/4"to 47-1/2'(82.5 mm to 1,207 mm)for the adjustable recessed style. <br /> Lengths exceeding the standard lengths are available,with no approvals,on a"made-to-order'basis:Recessed Dry HSW up to 65- <br /> 1/2"(1,664 mm).Adjustable Standard Dry HSW up to 63-1/2"(1,613 mm).Plain Barrel Dry HSW up to 65"(1,651 mm).Contact <br /> the manufacturer for more information. <br /> Finish Suffix:Brass=A,Chrome=F,White Polyester=M-/W, and ENT=JN <br /> Temperature Suffix: 155°F(68°C)= B, 175°F(79°C)=D,200°F(93°C)=E,286°F(141 °C)=G <br /> Escutcheon Suffix = Y for the adj. recessed sprinkler with the Model G-1 <br /> Escutcheon(no suffix needed for the Model E-1 Escutcheon). NOTE; Sprinkler is turned sideways <br /> For example, sprinkler VK182 with 1'NPT Threads,a Chrome finish,a 155 for clarity. (Refer to Figures 2-7 <br /> °F(68°C)temperature rating,the Model G-1 Escutcheon,and"A"length for correct deflector orientation.) <br /> of 10"=Part No.08386UFBY10. Protective <br /> Available Finishes And Temperature Ratings:Refer to Table 1. , Sprinkler <br /> Accessories:(Also refer to the"Sprinkler Accessories"section.) Shield <br /> Sprinkler Wrenches: '4/41111 <br /> 1 e • <br /> A. Standard Wrench: Part No.07297W/B(available since 1991) �yri1 hi I <br /> B.Wrench for recessed sprinklers:Part No.07565W/B"(available since 1991) , <br /> A'/z ratchet is required(not available from Viking). Il���i!■ <br /> � i <br /> Dry Sprinkler Protective Cover: Part No. 15610 ,:' A <br /> - � <br /> Replacement Escutcheons: <br /> A.Adjustable Standard Dry Escutcheon:Base Part No.08086F Wrench <br /> B. Model E-1 Recessed Dry Escutcheon Cup: Base Part No. 05459A Flat <br /> 4. INSTALLATION / \ <br /> Refer to appropriate NFPA Installation Standards. _ <br /> 5. OPERATION ! VIKING <br /> During fire conditions,the heat-sensitive liquid in the glass bulb expands, <br /> causing the glass to shatter,releasing the internal parts to open the water- <br /> way.Water flowing through the sprinkler orifice strikes the sprinkler deflector, Figure 1: <br /> forming a uniform spray pattern to extinguish or control the fire. Standard Sprinkler Wrench 07297W/8 <br /> 6. INSPECTIONS,TESTS AND MAINTENANCE <br /> Refer to NFPA 25 for Inspection,Testing and Maintenance requirements. <br /> 7. AVAILABILITY <br /> The Viking Quick Response Dry Horizontal Sidewafl Sprinkler is available through a network of domestic and international distribu- <br /> tors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. <br /> 8. GUARANTEE <br /> For details of warranty, refer to Viking's current list price schedule or contact Viking directly. <br /> TABLE 1:AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES <br /> Ordina 155°F 68°C 100°F 38°C Red <br /> Intermediate 175°F 79°C 150°F 65°C Yellow <br /> Intermediate 200°F 93°C 150°F 65°C Green <br /> Hi.h 286°F 141 °C 225°F 107°C Blue <br /> Sprinkler Finishes: Brass,Chrome,White Polyester,and ENT <br /> Corrosion-Resistant Coating':White Polyester and ENT in all temperature ratings <br /> Footnotes <br /> The sprinkler temperature rating is stamped on the deflector. <br /> 2 Based on NFPA-13.Other limits may apply,depending on fire loading,sprinkler location,and other requirements of the Authority Having Jurisdiction. <br /> Refer to specific installation standards. <br /> 'The corrosion-resistant Polyester and ENT coatings have passed the standard corrosion test required by the approving agencies indi- <br /> cated in the Approval Charts.These tests cannot and do not represent all possible corrosive environments. Note:These coatings are <br /> NOT corrosion proof.Prior to installation,verify through the end-user that the coatings are compatible with or suitable for the proposed <br /> environment.Polyester and ENT coatings are applied to the exposed exterior surfaces only.Note that the spring is exposed on sprinklers <br /> with Polyester and ENT coatings. <br /> 'When installed In some corrosive environments,the Polyester finish may change color.This natural discoloration over time is not in itself <br /> an Indication of corrosion and should not be treated as such.All sprinklers installed in corrosive environments should be replaced or <br /> tested as described in NFPA 25 on a more frequent basis. <br /> Form No. F_031993 Rev 15.1 <br />