My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Re: fuel storage tanks
Orono
>
Property Files
>
Street Address
>
N
>
North Shore Drive
>
3324 North Shore Drive - 08-117-23-41-0012/21 and 44/0005
>
Correspondence
>
Re: fuel storage tanks
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 5:47:08 PM
Creation date
11/15/2017 10:20:54 AM
Metadata
Fields
Template:
x Address Old
House Number
3324
Street Name
North Shore
Street Type
Drive
Address
3324 North Shore Dr
Document Type
Correspondence
PIN
0811723410021
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
11
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Mr. Jim Dunn <br /> Page 2 <br /> August 12, 1996 <br /> Monitoring Requirements: <br /> Monitoring should be conducted quarterly for the first six monitoring events. Thereafter <br /> monitoring should be conducted semi-annually until closure criteria are met(See"Closure <br /> criteria below). Monitoring should include: <br /> a) Measurement of water level and product thickness in all monitoring wells; <br /> b) Analysis of water samples from all monitoring wells for benzene, ethyl benzene, toluene, <br /> xylene,methyl tertiary butyl ether, a�:nd total petroleum hydro carbons usin�gasoline rar�ge <br /> organics and diesel range organics; <br /> c) Semi-annual vapor survey of utilities or structures that have the potential to be impacted by <br /> the release. <br /> Additional Work: <br /> Perform push probe ground water investigation and analysis at water table to show that plume is <br /> stable and not affecting surface water. Analyze ground water for gasoline range organics, diesel <br /> range organics,benzene,toluene, ethyl-benzene,xylene, and methyl tertiary butyl ether. <br /> Re�ortine: <br /> An annual progress report should be prepared arid submitted in accordance MPCA Fact Sheet <br /> #3.26,"Annual Monitoring Report,"April 1996. Results of the quarterly(or semi-annual) ' <br /> monitoring should be included in the annual report. Results of quarterly or semi-annual <br /> monitoring should simply be submitted to MPCA staff in tabulaz format. <br />
The URL can be used to link to this page
Your browser does not support the video tag.