My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Renovate/addition project manual-1997
Orono
>
Property Files
>
Street Address
>
N
>
North Shore Drive
>
2625 North Shore Drive - 09-117-23-42-0003
>
Misc
>
Renovate/addition project manual-1997
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 5:51:23 PM
Creation date
10/19/2017 12:55:24 PM
Metadata
Fields
Template:
x Address Old
House Number
2625
Street Name
North Shore
Street Type
Drive
Address
2625 North Shore Dr
Document Type
Misc
PIN
0911723420003
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
118
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SECT'ION 15150 � <br /> PIPING MATERIALS AND METHODS <br /> � <br /> 1.00 GENERAL <br /> A. All piping materials and methods of construcrion and workmanship shall be provided as � <br /> per the requirements of local codes and regulations. <br /> B. Slope water piping 1" per 40' and anange to drain at all low points. Slope waste piping � <br /> per Code. <br /> C. Lead pipe, solders, flux, etc., are not allowed. � <br /> D. The contractor is responsible for verifying all invert elevations with respect to building <br /> finished floor elevations and site provisions. � <br /> E. All underground sewer pipe within 10 feet of buried water supply piping shall be <br /> constructed in accordance with State and/or Local Code. <br /> F. Vent pipes passing through roofs shall ternunate at least 12" above the roof line. � <br /> G. Above grade plastic horizontal and vertical runs can not exceed 35 feet. Solvent welds � <br /> shall be done with a contrasting primer to the color of the pipe. <br /> H. All water distribution steel and wrought iron pipe, under floor in ground, shall be � <br /> encased with polyethylene. <br /> I. Provide valves as indicated on the drawings and as required by good installation <br /> practice for the proper isolation of equipment and branch piping. Provide extended � <br /> stem valves where required for insulation. Except as otherwise specified or shown on <br /> plans, valves 2-1/2 inch and smaller shall have screwed end connections and valves 3 <br /> inch and larger shall have flange end construction. Install manual drain valves at every � <br /> low point of each water piping system. <br /> J. All branch take offs shall have isolation shut off valves <br /> K. Sanitary,Vent and Waste � <br /> 1. Bell and spigot cast iron piping and fittings ASTM A-74 with neoprene <br /> compression joints. � <br /> 2. Hubless cast iron pipe and joint system, with stainless steel bands or MG cast <br /> iron couplings. <br /> 3. PVC Schedule 40, ASTM D2665 with mechanical ring or gasket ASTM 2321, or � <br /> fusion or solvent cement ASTM D2855. <br /> 4. Pressurized waste discharge (i.e. sump pumps, sewage ejectors, etc.) shall be <br /> schedule 40 galvanized steel. <br /> 5. Piping shall be laid on a continuous granular bed. ' <br /> L. Above Grade Domestic Water Piping <br /> 1. Type "L" hard drawn copper tubing with wrought copper fittings, using 95/5 � <br /> solder or brazing. <br /> 3. Provide a dielectric union at all junctions of dissimilar metals. <br /> � <br /> ��4=�y� CBA701 8/1/97 '� <br /> 15150- 1 <br /> � <br />