Laserfiche WebLink
' M. In handicapped living areas, controls or switches for ran e hoods, dis osals, <br /> g P <br /> undercabinet fixtures, etc. sha11 be installed in the kitchen cabinet face. <br /> � N. All receptacles and oudets located in block walls shall be mounted so that only one <br /> block is cut. <br /> � O. Receptacles and outlets located on opposite sides of a common wall shall not be <br /> mounted in the same stud space. At least one stud shall separate devices. <br /> ' P. Circuit numbers shown are for reference only within noted panel. Contractor shall <br /> neatly identify correct circuit numbers on the as-built drawings. <br /> ' Q. Where required, the Contractor shall provide GFI devices or GFI breakers per the <br /> NEC. <br /> � R. Contractor shall submit all fire stopping methods to the local authorities for approval. <br /> Provide copies of all approved fire stopping methods to the Engineer. <br /> S. Seal all penetrations and sleeves through floors and fire walls with a high temperature, <br /> ' fire rated sealant. Fire stop material shall be Chase Technology CTCPR-855 fire stop, <br /> 3M brand Fire Barrier Penetration System or Nelson Flameseal System. <br /> ' END OF SECTION <br /> � <br /> ' <br /> � <br /> � <br /> � <br /> � <br /> ' <br /> , <br /> , <br /> , RMAS CBA701 8/1/97 <br /> 032497 16050- 2 <br /> ' <br />