x Address Old
House Number
2865
Street Name
North Shore
Street Type
Drive
Address
2865 North Shore Dr
Document Type
Misc
PIN
0911723240001
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
126
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
, <br /> � <br /> 1 �laximum nominal size as follows: <br /> Footings: 1_y2+� <br /> � Masonry Fill: 1/4" <br /> All other concrete: 3/4" <br /> Fine A��re�ates: ASTM C33, natural bank or river sand. <br /> ' sUVater: Drinkable. <br /> ��' , � , � Air=Entrainin� Admixture: ASTM C 260, certified by manufacturer to be compatible <br /> , <br /> with other required admixtur�s. <br /> Products: Subject to compliance with requirements, provide one of the following: <br /> ' "Sika Aer"; Sika Corp. <br /> "MB-VR or MB-AE"; Master Builders <br /> � "Darex AEA"; W.R. Grace <br /> "Edoco 2001 or 2002"; Edoco Technical Products <br /> Prohibited Admixtures: Calcium chloride thyocyanates or admixtures containing more <br /> ' than 0.1 percent ch oride ions are not permitted. <br /> ' <br /> 2-Q�pROPORTIONING AND DESIGN OF MIXES: <br /> � Prepare desit�n mixes for each type and strengfh of concrete by either laboratory trial <br /> batch or field.experience methods as specified in ACI 301. If trial batch method used, <br /> use an independent testing facility acceptable to Architect for preparing and reporting <br /> ' proposed mix designs, The testing facility shall not be the same as used for field quality <br /> control testing. <br /> , <br /> � Desi4n,Mixe,s �� p�„ie� normai weignt concrete with the following properties, as <br /> in—d a ed on drawings and schedules: <br /> 4000 psi 28-day compressive strength; W/C ratio, 0.44 maximum (non-air- <br /> � entrained), 0.35 maximum (air-entrained). <br /> Adjustment to Concrete Mixes: Mix design adjustments may be requested by Contractor <br /> � when characteristics of materials, job conditions, weather, test results, or other <br /> � <br /> CONCRETE WORK 03310 - 3 <br /> � <br /> � <br />