Laserfiche WebLink
�._, � <br /> � ,:., <br /> CHAPTER 24 <br /> TENTS, CANOPIE� AND OTHER MEMBRANE STRUCTURES <br /> SECTION 2401 ance of 12 feet(3658 mm),not exceeding 700 <br /> GENERAL square feet(65 m')total. <br /> 2.3. A minimum clearance of 12 feet(3658 mm)to <br /> 2401.1 Scope.Tents,canopies and membrane structures shall all structures and other tents. <br /> comply with this chapter. The provisions of Section 2403 are <br /> applicable only to temporary membrane structures.The provi- 2403.3 Place of assembly.For the purposes of this chapter,a <br /> sions of Section 2404 are applicable to temporary and perma- place of assembly shall include a circus, carnival, tent show, <br /> nent membrane structures. theater,slcating rink,dance hall or other place of assembly in or <br /> under which persons gather for any purpose. <br /> SECTION 2402 2403.4 Permits.Permits shall be required as set forth in Sec- <br /> DEFINITIONS tions 105.6 and 105.7. <br /> 2403.5 Use period. Temporary tents, air-supported, <br /> 2402.1 Definitions.The following words and terms shall,for air-inflated or tensioned membrane structures and canopies <br /> the purposes of this chapter and as used elsewhere in this code, shall not be erected for a period of more than 180 days within a � <br /> have the meanings shown herein. 12-month period on a single premises. <br /> AIR-SUPPORTED STRUCTURE.A structure wherein the 2403.6 Construction documents. A detailed site and floor <br /> shape of the structure is attained by air pressure,and occupants p��n for tents,canopies or membrane structures with an occu- <br /> of the structure are within the elevated pressure area. pant load of 50 or more shall be provided with each application <br /> CANOPY. A structure, enclosure or shelter constructed of for approvaL The tent, canopy or membrane structure tloor <br /> fabric or pliable materials supported by any manner,except by plan shall indicate details of the means of egress facilities,seat- <br /> air or the contents it protects,and is open without sidewalls or ing capacity,arrangement of the seating and location and type <br /> drops on 75 percent or more of the perimeter. of heating and electrical equipment. <br /> MEMBRANE STRDCTURE. An air-inflated, air-sup- 2403.7 Inspections.The entire tent,air-supported,air-inflated <br /> ported, cable or frame-covered structure as defined by the or tensioned membrane structure system shall be inspected at <br /> International Building Code and not otherwise defined as a regular inCervals, but not less than two times per permit use <br /> � Cent or canopy. See Chapter 31 of the International Building period, by the permittee,owner or agent to determine that the <br /> Code. installation is maintained in accordanee with this chapter. <br /> TENT.A structure,enclosure or shelter constructed of fabric Exception:Permit use periods of less than 30 days. <br /> or pliable material supported by any manner except by air or 2403.7.1 Inspection report.When required by the fire code <br /> the contents that it protects. official, an inspection report shall be provided and shall <br /> consist of maintenance,anchors and fabric inspections. <br /> SECTION 2403 2403.8 Access, location and parking. Access location and <br /> TEMPORARY TENTS, CANOPIES AND MEMBRANE parking for temporary tents, canopies and membrane struc- <br /> STRUCTURES tures shall be in accordance with this section. <br /> 24031 General.All temporary tents,canopies and membrane 2403.8.1 Access.Fire apparatus access roads shall be pro- <br /> structures shall comply with this secrion. vided in accordance with Section 503. <br /> 2403.2 Approval required. Tents and membrane structures 2403.8.2 Location.Tents,canopies or membrane structures <br /> having an area in excess of 200 square feet(19 m�)and cano- shall not be located within 20 feet(6096 mm) of lot lines, <br /> pies in excess of 400 square feet(37 m�) shall not be erected, buildings, other tents, canopies or membrane structures, <br /> operated or maintained for any purpose without first obtaining p�ked vehicles or internal combustion engines.For the pur- <br /> a permit and approval from the fire code official. pose of determining required distances, support ropes and <br /> �uy wires shall be considered as part of the temporary mem- <br /> Exceptions: brane structure,tent or canopy. <br /> 1. Tents used exclusively for recreational camping pur- Exceptions: <br /> poses. L Separation distance between membrane struc- <br /> 2. Fabric canopies open on all sides which comply with tures, tents and canopies not used'for cooking, is <br /> all of Che following: not required wben the aggregate floor area does <br /> 2.1. Individual canopies having a maximum size not exceed 15,000 square feet(1394 m�). <br /> of 700 square feet(65 m'). 2. Membrane structures, tents or canopies need not <br /> 2.2. The aggregate area of multiple canopies be separated from buildings when all of the follow- <br /> placed side by side without a fire break clear- ing conditions are met: <br /> 231 <br /> j 2007 MINNESOTA STATE FIRE CODE <br /> � <br />