Septic info(including 2006 septic design)
Orono
>
Property Files
>
Street Address
>
L
>
Landmark Drive
>
50 Landmark Drive - 05-117-23-21-0019
>
Septic
>
Septic info(including 2006 septic design)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 5:19:22 PM
Creation date
10/11/2017 9:51:37 AM
Metadata
Fields
Template:
x Address Old
House Number
50
Street Name
Landmark
Street Type
Drive
Address
50 Landmark Dr
Document Type
Septic
PIN
0511723210021
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
22
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
DOSING CHAMBER SIZING <br /> All boxed rectangles must be errtered,the►esf will be cakulated. Width <br /> 1. Determine area <br /> A. Rectangle area=L x W <br /> �� ft x �ft = 0 f� Length <br /> B. Circle area=3.14 x radius2 <br /> 3.14 x 2 ft = 0.0 it� <br /> C. Get area from manufacture it� Radiu <br /> 2. Calculate galbns per inch <br /> There are 7.5 gallons per cubic foot of volume,therefore multiply the area(1A,B or C) <br /> 6mes the conversion factor and divide by 12 inches per foot to ca�ulate galbn per inch. <br /> Surface area x 7.5/12= 0� x 7.5 / 12in/ft = 29.41 gallon per inch Legal Tank: <br /> •PER DARWIN PRECAST 500 gallons or <br /> 3. Calculate total tank volume 100%the daily flow <br /> A. Depth from bottom of inlet pipe to tank bottom 52 in or Afternating Pumps <br /> B. Total tank volume=depth from bottom of inlet pipe to tank bottom(3A)x gaUn(2) ,4i:c�,,,,,,d a.�o•a�.ti s�v oou <br /> = 52 in x 29.41 gal�n = 1529.3 galbns �� �� �� ��� �N <br /> 4. Calculate gallons to cover pump(with 2-3 inches of water covering pump) a � ��'oo i�a d�"i►,. <br /> (Pump and block he' ht+2 inches)x gallon per inch s � � �4 �` <br /> ( 12 + 2 in) x 29.41 gal�n = 411.7 gallons � � � � �'°'� <br /> � ,oso eao �o �.a.a <br /> e �2m e�s eoe �a►.f... <br /> 5. Ca�ulate total pumpout volume <br /> A. Select pump size for 4-5 doses per day. Galbn per dose=gpd(see Figu�A-1)/dases per day= <br /> 750 gpd 1 04 doseslday = 187.5 gallons <br /> B. Calculate drainback <br /> 1. Determine total pipe length 205.0 ft � <br /> 2. Determine liquid volume of pipe, gaUft(see figure E-20) � <br /> 3. Drainback quanGty= 205.0 ft(561) x 0.17 gal/ft(562) 34.9 y E-20: V�lume of Li uia ia Pi e <br /> C. Total pump out volume=dose volume(5A)+drainback(583) �pe��eter Gallons per foot <br /> 187.5 gallons+ 34.9 gallons= 222.4 1 0.045 <br /> 1.2.5 0.078 <br /> 6. Calculate float separation distance(using total pumpout volume) 1.5 0.11 <br /> 2 0.17 <br /> Total pumpout volume(5C)I gal�nch(2) 2.5 0.25 <br /> 222.4 gal / 29.41 ga�n = 7.6 inch 4 o.b�b <br /> 7. Ca�ulate volume for alartn(iypically 2-3 inches <br /> Alarm depth(inch) x gallon�nch(2) = 3 in x 29.41 gaUn = 88.23 gal <br /> 8. Calculate total galbns=gallons over pump(4)+gallons pumpout(5C)+gallons alartn(7) <br /> 411.7 gal + 222.4 gal + 88.23 gal = 722.3 gal <br /> 9. Total tank depth=total gallons(8)/gallon�n(2) ' <br /> 722.3 gallons/ 29.41 gal�n = 24.6 p� <br /> � e,s�rv�e ca�cit ` <br /> � aiann on <br /> Recommended ; _ oont�a <br /> o pimpout vd ume <br /> Calculate reserve capacity(75/o of the daily flow) � __�____________ __ _ punp on <br /> Dail flow x 0.75 = 750 x 0.75= 562.5 allons € ��� � coMra <br /> I hereby certity I completed this work in accordance with all applicable ordinances,rules and laws <br /> (si9nature) l l`� (license#) Z'27z� (date) <br />