Laserfiche WebLink
ESR-1074 I Most Widely Accepted and Trusted Page 2 of 2 <br /> Rabbeted Cornerboards and Trimboards are produced the seam/edge of panels. AZEK® Trimboards nominally <br /> with a 3/4-inch (19 mm) square removed from each edge. 1 inch and 11/4 inches thick must have a maximum <br /> The AZEK® Rabbeted Cornerboards are available in a allowable design load of 60 psf (2880 N/m2) suction, <br /> nominal thickness of 5/4 inches, nominal widths of 4, 6 and negative wind load. <br /> 8 inches, and lengths of 10 and 20 feet (3 m and 6 m). <br /> AZEK® Rabbeted Trimboards are available in a nominal 5.0 CONDITIONS OF USE <br /> thickness of 5/4 inches, nominal widths of 4, 6 and The AZEK®Trimboards Traditional,AZEK®Millwork, AZEK <br /> 8 inches, and a length of 18 feet (5.4 m). AZEK Column to Mik AZEK®Trimboards Frontier Series, AZEK®Sheets, <br /> Wrap consists of three connected panels and a fourth AZEK Beadboard,AZEK®Cornerboards AZEK®Universal <br /> locking panel that secures the Column Wrap in place. Skirt Board, AZEK® Finish Grade Trim, AZEK® Integrated <br /> AZEK Column Wrap is 1/2 inch thick and has actual outside Drip Edge, AZEK® Rabbeted Cornerboards, AZEK® <br /> dimensions of 43/4 inches,63/4 inches,or 83/4 inches, and is Rabbeted Trimboards and AZEK Column Wrap described <br /> installed around a nominal 4-by-4, 6-by-6 or 8-by-8 wood in this report comply with, or are suitable alternatives to <br /> column or post. AZEK Column Wrap is available in what is specified in, those codes listed in Section 1.0 of <br /> 10-foot lengths. this report, subject to the following conditions: <br /> All AZEK products covered under this evaluation report, 5.1 This evaluation report and the manufacturer's <br /> up to a maximum nominal thickness of 6/4 inches, and published installation instructions, when required by <br /> AZEK® Finish Grade Trim at a maximum nominal installed the code official, must be submitted at the time of <br /> thickness of 6/4 inches, have a flame-spread index of less permit application. <br /> than 25 when tested in accordance with ASTM E84. 5.2 The trim must be manufactured, identified and <br /> 4.0 INSTALLATION installed in accordance with this report and the AZEK <br /> 4.1 General: Building Products instructions. <br /> 5.3 The product is limited to the following construction <br /> AZEK Trimboards Traditional, AZEK® Millwork, AZEK to <br /> Mill, AZEK® Trimboards Frontier Series, AZEK® Sheets, types. <br /> AZEK®Beadboard,AZEK®Cornerboards AZEK®Universal 5.3.1 Nonload-bearing exterior trim on buildings <br /> Skirt Board, AZEK® Finish Grade Trim, AZEK®Integrated of combustible non-fire-resistance-rated <br /> Drip, AZEK® Rabbeted Cornerboards, AZEK® Rabbeted construction(Type VB of the IBC). <br /> Trimboards and AZEK Column Wrap must be installed in 5.3.2 Architectural trim on buildings of Type I, II, Ill <br /> accordance with the manufacturer's published installation and IV construction under the IBC, that do not <br /> instructions and this report. exceed 40 feet(12.2 m) in height above grade. <br /> The manufacturer's published installation instructions The trim must be backed by noncombustible <br /> and this report must be strictly adhered to, and a copy of construction. The trim is limited to ten percent <br /> the instructions must be available at all times on the of the exterior wall surface area where the fire <br /> jobsite during installation.The instructions within this report separation distance is 5 feet(1.52 m)or less. <br /> must govern if there are any conflicts between the 5.3.3 All construction types permitted under the IRC. <br /> manufacturer's published installation instructions and <br /> this report. 5.4 The product must be installed over solid backing <br /> 4.2 Fasteners: material, such as approved exterior sheathing <br /> covered with an approved water-resistant barrier or <br /> Fasteners must be stainless steel or hot-dipped approved exterior wall covering. <br /> galvanized, and must be approved box nails or finish wood 6.0 EVIDENCE SUBMITTED <br /> screws designed for wood trim and wood siding with a <br /> thinner shank. Nails must have blunt points and full- Data in accordance with the ICC-ES Acceptance Criteria <br /> rounded heads. The fasteners must be long enough to for Rigid Cellular PVC Nonload-Bearing Exterior Trim <br /> penetrate the solid wood substrate a minimum of (AC227), dated December 2004 (editorially revised <br /> 11/2 inches (38.1 mm). The fasteners located at board June 2012). <br /> ends must be placed no more than 2 inches (50.8 mm) 7.0 IDENTIFICATION <br /> from the end of the board. <br /> 4.3 Wind Load Assembly—Soffits Using AZEK® Each package of AZEK® Trimboards Traditional, AZEK® <br /> Trimboards: Millwork, AZEK to Mill, AZEK Trimboards Frontier Series, <br /> AZEK Sheets, AZEK® Beadboard, AZEK Cornerboards <br /> AZEK®Trimboards measuring a minimum of 12 inches by AZEK® Universal Skirt Board, AZEK® Finish Grade Trim, <br /> 48 inches (304.8 mm by 1219.2 mm) must be installed AZEK® Integrated Drip Edge, AZEK® Rabbeted <br /> on minimum 2-by-4 wood framing SPF stud grade Cornerboards AZEK® RabbetedTrimboards and AZEK <br /> (G = 0.42) spaced 16 inches (406.4 mm) on center. The Column Wrap described in this report must be labeled with <br /> AZEK® Trimboards are placed with the long direction the CPG Building Products LLC name, address and <br /> perpendicular to the wood framing and are fastened telephone number; the product trade name; and the <br /> to each of the wood members with two 31/4-inch-long evaluation report number(ESR-1074). <br /> (82.55 mm), 16d box nails, located 1 inch (25.4 mm) from <br />