[ <br /> 1991 UNIFORM FIRE CODE 32.110-32.114 <br /> II ,: <br /> Standby Personnel �,� � i „:� <br /> Sec.32.110. Qualified persons necessary [o safeguazd the premises shall be <br /> provided as required and approved by the chief. <br /> Exits <br /> Sec.32.111. (a) Distribution. Exits shall be spaced at approximately equal <br /> intervals around the perimeter of the [ent, canopy or temporary membrane <br /> structure and shall be so located that no point is more than 100 feet from an exiL <br /> (b) Number.Exits shall be provided in accordance with Table No.32.111-A. F'� <br /> (c) Openings.Exit openings from tents shall remain open unless covered by a <br /> flame-retardant curtain,provided: . �� <br /> 1. Said curtains shall be free sliding on a metal support.The support shall be a <br /> minimum of 8 feet above the floor level at the exit. The curtains shall be so � <br /> arranged tha[,when open,no part of the curtains shall obstruct the exiL <br /> 2. Said curtains shall be of color,orcolors,contrasting wi[h the colorof the tent. .�Y �� �� <br /> f- <br /> (d) Doors.Exit doors from air-supported structures shall swing in the direction : <br /> of exit travel.To avoid hazardous pressure loss,such doors shall be automatic �f` <br /> z; <br /> closing against operating pressures. Opening force at the door edge shall not <br /> exceed 15 pounds. <br /> �.�: <br /> (e) Aisles.Aisles having minimum width of not less than 44 inches shall be <br /> provided from all seating areas,and their width shall be progressively increased in <br /> width to provide a[all points not less than 1 foot of aisle width for each 50 persons x� } �r�,�� '�', s i�*�°~ <br /> served by such aisle at that point. ' .�'��� 1,� �}+a��� c�,� ` <br /> The arrangement of aisles shall be approved by the chief. •'�'�� �`�� �'�x,,3�� <br /> r, <br /> �: ����� ` <br /> Maintenance of Exit Ways 4{' �^~f�; <br /> " ���" <br /> Sec•32.112.Therequiredminimumcleazwidthofexits,aislesandpassageways '" * €` <br /> shall be maintained at all times to a public way. ° 4 :fixr ,'�� ����y �' <br /> Guywires, guyropes and other support members shall no[cross a means of ���ror �'�, <br /> ,., t '`�'j'' s�' < <br /> egress at a height of less than 8 feet �� ���'; <br /> The surface of exitways shall be maintained in a manner approved by the chief. � p ���` '"� :�` <br /> w <br /> Exit Illumination ��+ ` <br /> �. � �„z�. ��t� ' <br /> Sec.32.113.Exits shall be illuminated with light having an intensity of not less� { �� �' <br /> �han one footcandle at floor level while struc[ure is occupied.Fixtures required for <br /> exitilluminationshallbesuppliedfromaseparatecircuitorsourcesofpowerwhen � � <br /> these are required for exit signs by Section 32.114(b). ��f ��- <br /> � <br /> Exit Signs `'� '` <br /> � <br /> Sec•32.114.(a)When Required.Exit signs shall be installed at required exit <br /> dOorways and where otherwise necessary to clearly indicate the direction of egress t' <br /> w'hen the exit serves an occupant load of 50 or more. Ixy <br /> (b) Illumination.Exit signs in tents,canopies and temporary membrane struc- <br /> i <br /> ' tures with occupan[loads over]00 persons shall be of an approved self-luminous <br /> , <br /> � <br /> �. <br /> � <br /> � � <br /> � -� rt <br /> w: <br /> � � ,., ,. ,., . . . �., <br />