My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COO testing maual
Orono
>
Property Files
>
Street Address
>
N
>
North Shore Drive
>
2240 North Shore Drive - 10-117-23-32-0019
>
Misc
>
COO testing maual
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 3:26:22 PM
Creation date
10/4/2017 11:52:24 AM
Metadata
Fields
Template:
x Address Old
House Number
2240
Street Name
North Shore
Street Type
Drive
Address
2240 North Shore Drive
Document Type
Misc
PIN
1011723320019
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
12
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SYSTEM#5—ELEVATOR SYSTEM <br /> A. SEQUENCE OF OPERATION: <br /> Onty smoke detectors in the elevator lobby or elevator machine room have the capability of <br /> initiating the elevator recall to the primary floor(1� Floor). If the 15t floor lobby smoke <br /> detector was initiated the elevator will recall to an alternate floor(2nd Fioor). Once elevators <br /> have reached their recail floor they are set for fire department use. <br /> In addition to the smoke detectors, there are heat detectors located in the elevator machine <br /> room and elevator shaft pit. Activation of either of these heat detectors wili shunt power to <br /> the elevator. <br /> B. TEST PROCEDURE: <br /> During the test of the fire alarm devices, confirm that the elevators are responding properly. <br /> Observe and record return of elevators to primary floor. Set any fire alarm device on primary <br /> floor into alarm and observe and record return to alternate floor. Under fire mode observe <br /> and record that elevator control can only be initiated by fireman's override key. Observe and <br /> record the proper operation of the telephone and intercom in each elevator. <br /> C. TEST EQUIPMENT: <br /> D. TEST REPORT FORMAT: <br /> Record elevator recall to primary and secondary floor. Record correct elevator annunciator <br /> panel read out. <br /> E. TEST PARTICIPANTS: <br /> Mortenson, Elliott Contracting, Elevator Contractor <br /> Minnetonka Center for the Arts 9 <br /> Certificate of Occupancy Testing Manual <br />