, <br /> 2. (UBC 305.2.1) Buildings or parts of building classed in Group E because of the use <br /> or character of the occupancy shall be limited to the types of construction set forth in <br /> Table 5-B and shall not exceed, in area or height, the limits specified in Sections <br /> 504, 505, 506, excent that the area may be increased b,�50 percent when the <br /> maximum travel distance specified in Section 1004.2.5 is reduced bv 50 percent. <br /> (1007.3.3.1 UBC)From Rooms: Max travel distance to corridor or exit =75' <br /> In buildings not more than 2 stories with smoke detectors=90' <br /> In buildings with automatic sprinkler system =110' <br /> (1007.3.3.2 UBC)From Any Location: Max travel distance =150' <br /> In buildings not more than 2 stories with smoke detectors=175' <br /> In buildings with automatic sprinkler system =225' <br /> Group E allowable area=27,OOOsqft X 50%=40,SOOsqft. <br /> Total Allowable Area <br /> Group E =40,SOOsqft <br /> Group A 3 =18,200sqft <br /> Group A 2.1 =27,OOOsqft <br /> Group B =24,OOOsqft <br /> 8. Allowable Height <br /> A. As per Table 5-B (UBC)the allowable height is the following: <br /> Group E Type II N construction One Story 55 feet <br /> Group A 3 Type II N construction One Story 55 feet <br /> Group B Type II N construction Two Stories 55 feet <br /> B. (506 UBC)The story limits set forth in Table 5-B may be increased by one story if the <br /> building is provided with an approved automatic sprinkler system throughout. <br /> Group E Type II N construction Two Story 55 feet <br /> Group A 3 Type II N construction Two Story 55 feet <br /> Group B Type II N construction Three Stories 55 feet <br /> (The increase in the number of stories may not apply when the automatic sprinkler systems throughout aze installed <br /> under the following provisions:..2. Section 505 for an increase in allowable uea. 3. Substitudon for one-hour fire <br /> resistive construction pursuant to Section 508.) <br /> C. (506 UBC) Exception to Height Limit. Towers, spires and steeples erected as part of a <br /> building and not used for habitation or storage are limited as to height only by structural <br /> design if completely of noncombustible materials, or may extent not to exceed 20 feet above <br /> the height limit in Table 5-8 if or combustible materials. <br /> D. City of Orono Height Limit. (Sec. 10.28.RR-1B One Family Rural Residential District.) <br /> Subd.5. Area,Height,Lot Width and Yard Requirements. <br /> A.Height.No structure or building shall exceed 2 1/2 stories or thirty feet in height <br /> except as provided in Section 10.75. <br /> Seciton 10.75 Height of Structures. <br /> Subd. 1.Special provisions. The height limitations imposed by other provisions of this <br /> Chapter may be increased by conditional use permit by 50 percent when applied to the <br /> following structures. <br /> L.Cooling Towers. <br />