Laserfiche WebLink
M <br /> ✓ Occupant Load: Based on the exisdng floor area of two main floor classroams @ 663 s.f.each. <br /> • Main Floor, 1326 s.f.of classroom,Group E-1 @ 1 occupant/20 s.f.=66 occupants. <br /> Based on the existing upper azea of 1575 s.f.. <br /> • Upper Floor,659 s.f.of classroom,Group E-1 @ 1 occupant/20 s.f.=33 occupants. � � <br /> • Upper F1oor,576 s.f.of office,Group E-1 @ 1 occupant/100 s.f.=6 occupants. <br /> • Upper F1oor, 340 s.f.of library,Group E-1 @ 1 occupant/50 s.f.=7 occupants. ' <br /> With an occupant load of 46,occupancy posting will not be required at the upper level. <br /> Exidng: Based on occupant load,our existing exit widths and locations will be adequate. Two exits are <br /> required from both upper and lower levels. <br /> • Exit doors will be required to swing in the direction of travel at the main level entry doors. (1 <br /> � • Exit doors will not be required to have panic hardware. � � 5p ��Q nr.r�'��i . �1��^,��"'sv� <br /> • We will be required to accommodate accessibility at the main level front entry doors.�� <br /> • Exits will be req�ired to have illuminated exit signs. `�� <br /> • Existing exiting patterns from the lower level will be allowed to remain. s���� (��� <br /> • The exteriar stair and landing at the rear basement door will have to be reconstructed to <br /> accommodate stair rise and run,landing clearances and handraiUguardrail requirements. ��7 <br /> • The exteriar stair and landing at the rear main floor doors wili have to be verifie<1 and Q� <br /> reconstructed to accommodate stair rise and run, landing clearances and handraiUguardrail � <br /> requirements. <br /> �.• The exterior exit stair from the rear upper level door will have to be verified or reconswcted to <br /> accommodate stair rise and run,landing clearances and handraillguardrail requirements.The <br /> determinadon of an exterior exit stair satisfying exiting requirements for a Group E occupancy <br /> will have to be verified with the State Fire Marshal. �,�� � �� � �X.�-�u� 5��(� <br /> Accessibility: Requirements for main level accessibility of will have to be satisfied. <br /> • A ramp to the main entry doar will have to be provided. <br /> • Lever operated door hazdware will have to be provided at all main level and upper level doors. <br /> • A continuous handrail will have to be provided at all interior stairs. <br /> • Accessible toilet facilities will be required at the main level. <br /> Plumbing: Plumbing fixture counts,as required to be provided by UBC Ch.29,will be discussed upon further <br /> review. <br /> • We will be required to provide accessible plumbing facilities in accordance with UBC Ch. 11 & <br /> MN Ch. 1340. <br /> • We would prefer to reconfigure the existing plumbing azea to accommodate one unisex accessible <br /> lrathroom,one unisex non accessible bathroom and one accessible drinking fountain. <br /> • We will not be reyuired to provide a drinking fountain on t6e upper levei. <br /> Sprinklers: Sprinkler system requirements: <br /> • A sprinkler system is required in basement areas of Group E-1 occupancies. <br /> �• A sprinkler system will also be required to substitute far the required one hour rated construction. <br /> • The existing weA flow test(reported by the users group)indicated an eacisting flow rate of 50 gpm, <br /> w/a flow rate of 175 gpm required. It will be up to the well drilling company to determine if a <br /> new well will be able to accommodate if the additiona1125 gpm required. <br /> • The issue of sharing a well with another facility will have to be reviewed but seems unlikely. This <br /> would also require the flow rate for the other well to be tested. <br /> • A tank system,w/the tank located in the basement of the structure may be reyuired if well flow <br /> requirements cannot be met. <br /> 2of3 <br />