Laserfiche WebLink
Document management portal powered by Laserfiche WebLink 9 © 1998-2015 Laserfiche. All rights reserved.
On the North Shore of <br /> Lake Minnetonka <br /> ON-SITE SEWAGE TRfATMENT <br /> INSPECTION REPORT � POST OFFICE BOX 66 <br /> � _ � 1335 S. 6rown Rd. <br /> Crystal Bay, MN 55323 <br /> 473-7357 <br /> OWNER ��� �(YL� �► ' ADDRESS s���Iv�r�"h� /4r'm LR�1� <br /> PERMIT NO.'s. 3a� -[��'r- DATES �- �n"�3 CONTRACTORS w��!�+'+pr B/bs, <br /> City Ordinance No. 210 requires that eech on-site sewage treatment system in Orono be inapected on a regular basia.The on�site sewage <br /> treatment system at the above address has been inspected and appears to fall into the category checked below. <br /> (This is �an existing system ❑ new construction) <br /> � � Meets or exceeds current City standards in all respects relating to design,construction,and location.Appears to be operating <br /> properly. <br /> � 2 Does not meet all current City standards for new construction (1978 Co�) but in most respects appears to be designed, <br /> loceted, and constructed generally in accordance with previous codes.System appears to be functioning properiy;no major <br /> upgrading of the system is required at this time. <br /> � 3 Dces not meet Current City standards in many respects relating to design,construction,or location.Appears to be operating <br /> adequately at this time,but has a relatively high potential for future problems. No major upgrading of system is required at <br /> this time. <br /> � 4 System may or may not meet current City standards for design,construction or tocation, but is failing to properly treat a�d <br /> dispose of the current input,and is endangering a water supply,or is a source of po�lution to surface or groundwaters,or is <br /> creating a safety hazard,or is otherwise creating a public nuisance.Please contact the City Inspector to discuss system repair/ <br /> replacement procedures. If drainfield replacement is necessary,soil testing will usually be required,and a design and site plan <br /> must be submitted for review.Your contractor must obtain a permit before work is started. <br /> SYSTEM CONDtTION ( m Checked items may require your action) <br /> Tank inspection indicates: ❑ lnspection pipe is located directly over tank beffle.(Does not <br /> ❑ Pumpout not needed at this time. give accurate meesurement of solids accumulation.) If tanks <br /> �Solids aecumutation in tanks indicates they ahould be pump- have not been pumped out within the last three years,they <br /> ed out this year to help prevent future problems. should be pumped out now. <br /> ❑ Solids accumulation in tanks is at a critical levet, Tanks Drainfield ipspection indiceter. <br /> should be pumped out as soon as possible. �'Drainfield is dry,no surfacing evident. <br /> ❑ System is discharging to surface. Tanks must be pumped ❑ Some evidence of surfaci�g,not critical yet. <br /> within 48 hours to eliminate surface discharge, ❑ Drainfield is saturated and visibly diacharging untreated <br /> ❑ Inspection risers missing—tanks could not be inspected, effluent to the surface. This condition mey require replace- <br /> Inspection risers (4" dia. pipe)must be installed in each tank ment or additions to drainfield. Contact the City Inspector <br /> at next pumpout. If tanks have not been pumped out within immediately.Repairs must be completed within 90 days. <br /> the last three years,they should be pumped out now. ❑ Drainfield exte�t and condition unknown. <br /> SITE CHARACTERISTICS <br /> Limiting Site Factors Potential for.System Failure Site Capabilities for <br /> ❑ Slope (depends on soil types,water Future Expansion <br /> ❑ Soil � table,and system condition) Adequate <br /> ❑ High water table ❑ Low �Fair <br /> O Lot size �Medium\p�¢���9 on ❑Poor <br /> ❑ Lake,wetland,or stream �High; � l.t5cte�e ❑ Inadequate <br /> ❑ Drainage ❑System is causing visible <br /> surface diacha�ge. <br /> COMMENTS: <br /> � - 1y-g� <br /> �ate of Inspection Septic S nspector <br /> Note: In the event that this inspection report is used to satisfy the requi�ements for a mortgage or other transfer of property,be advised that <br /> this report does not guarantee or certify that an existing system will continue to function prbperly,but,is merely an opinion of the a�quacy <br /> of the system under current conditions based on the available inf�mation. <br /> This report must be kept orr the premises with systerns,location artd pumping records. <br /> • WH1TE COPY/Inspector's File : GOLD COPY/Homeowner <br />