Laserfiche WebLink
. . . . <br /> CITY OF ORONO �O� <br /> Municipal Offices O O <br /> Post Office Box 66 <br /> Crystal Bay, MN 55323-0066 � � ON—SITE SEWA(�E TREATNIENT <br /> � F INSPECTION REPORT <br /> ti <br /> ��9k'Esxo�`'�o <br /> Owner• K. Address• �S /�/11�1/!K'� KQ,• <br /> Permit #'s: �7 � <br /> s Dates: 7-7-►�� Contractors: <br /> City ordinance nu�er 100 requires that each on-site sewage treatment system in Orono be inspected on a regular basis. <br /> The on-site sewage treatment system at the above address has been inspected and appears to fall into the category <br /> checked below. <br /> (This is � an existing system [ ] new construction> <br /> SYSTEM CONFORMITY (1-3): <br /> 1 "CODE SYSTEM"-A system which meets all the location, design, and construction standards of the current City <br /> Codes, and which is operating satisfactorily by treating and disposing of the entire current sewage input <br /> without discharging any pollutants into ground or surface waters. <br /> 2 "CONFORMING SYSTEM��-A system uhich does not meet all the location, design, and construction standards of the <br /> current City Codes, but uas installed according to the code in effect at the time of installation, and which � <br /> is operating satisfactorily by treating and disposing of the entire current sewage input without discharging <br /> any pollutants into ground or surface waters. <br /> 3 "NON-CONFORMING SYSTEM"-A prohibited system; a system located within a designated 100-year floodplein; any <br /> system which mey or may not meet all the location, design, and construction standards of the current City <br /> Codes and which is failing for any reason; .and any system with less than 3 feet of unsaturated soil or sand <br /> . between the distribution device and the lim�ting soil characteristics. <br /> (The limiting soil characteristic [ ] has or [ ] has not been identified at this time. If the limiting soil <br /> characteristic has not been identified, this classification may be subject to revision.) <br /> TANK CONDITION (5-10): <br /> Tank inspection indicates: <br /> 5 Punpout not needed at this time. <br /> 6� Solids accunulation in tanks indicates they should be out this year to help prevent future roblems. <br /> �T1 Solids accunulation in tanks is at a critical level. a out <br /> 8 System is discharging to the surface. Tanks must be n ours ace dischar�e. <br /> 9 Inspection risers missing-tanks could not be inspected. Inspection risers (4" dia. pipe) must be installed tn each <br /> tank at next pumpout. If tanks have not been punped out within the last three years, they should be pumped <br /> out now. <br /> 10 Inspection pipe is located directly over tank baffle (does not give accurate measurement of solids accunulation). <br /> If tanks have not been punped out uithin the last three years, they should be pixnped out now. <br /> DRAINFIELD CONDITION (77-14): <br /> Dpe,�nfield inspection indicates: <br /> (1'p Drainfield is dry, no surfacing evident. <br /> �12 Sane evidence of surfacing, not critical yet. <br /> 13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector <br /> immediately. Repairs must be canpleted within 90 days. <br /> 14 Drainfield extent and condition unknown. <br /> LIMITING SITE FACTORS (slope,setbecks,etc.): <br /> POTENTIAL FOR SYSTEM FAILURE (decends on soils,water table,etc.): <br /> COMMENTS: <br /> Date of Inspection eptic System Inspector <br /> Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of <br /> property, be advised that this report does not guarantee or certify that an existing system will continue to function <br /> properly� but is merely an opim on of the adequacy of the system under current conditions based on the available <br /> information. <br /> This report must be kept on the preinises with the system locstion and pumping records. <br /> WHITE COPY/Inspectors File YELLOW COPY/Homeowner <br />