My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
septic info
Orono
>
Property Files
>
Street Address
>
M
>
Myrtlewood Road
>
25 Myrtlewood Road - 36-118-23-33-0014
>
Septic
>
septic info
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 5:03:19 PM
Creation date
8/1/2017 1:40:29 PM
Metadata
Fields
Template:
x Address Old
House Number
25
Street Name
Myrtlewood
Street Type
Road
Address
25 Myrtlewood Road
Document Type
Septic
PIN
3611823330014
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
9
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
. , � <br /> CITY OF ORONO �O� <br /> Municipal Offices O O <br /> Post Office Box 66 <br /> Crystal eay, MN 55323-0066 � � ON—SIT� SEWA(�E TREATl�NT <br /> INSPECTION REPORT <br /> ti <br /> h <br /> ��9k o4�G <br /> EsH <br /> Owner• Address• <br /> Permit #'e: Dates: � Contractors: �77 � rY.A�< <br /> City ordinance number 100 requires that each on-site sewage treatment _system in Orono be inspected on a regular besis. <br /> The on-site sewage treatment system at the above address has been inspected and appears to fall into the category <br /> checked below. <br /> (This is � an existing system [ ] new construction) <br /> STSTEM CONFORMITY (1-3): <br /> 1 "CODE STSTEM"-A system which meets all the location, design, and construction standards of the current City <br /> Codes, and which is operating satisfactorily by treating and disposing of the entire current sewage input <br /> without discherging any pollutants into ground or surface weters. <br /> 2 "CONFatMING STSTEM"-A system which does not meet all the location, design, and construction standards of the <br /> current City Codes, but was instelled according to the code in effect at the time of instellation, and which <br /> is operating satisfectorily by treating and disposing of the entire current sewage input without discharging <br /> any pollutants into gro�x�d or surface waters. <br /> 3 "NON-CONF�tMING SYSTEM"-A prohibited system; a system located within a designated 100-year floodplain; any <br /> system which may or mey not meet alt the location, design, and construction standards of the current City <br /> Codes and which is faili for any reason; and any.system with less than 3 feet of �saturated soil or sand <br /> between the distribution�vice and the limiting soil characteristics. <br /> (The limiting soil characteristic [ ] has or�has not been identified at this time. If the timiting soil <br /> characteristic has not been identified, this M assification may be subject to revision.) <br /> TANK CONDIT[ON (5-10): <br /> Tank inspection indicates: <br /> 5 Pumpout not needed at this time. <br /> 6 Solids accumulation in tanks indicates they should be pu�ed out this year to help prevent future problems. <br /> 7 Solids accunulation in tanks is at a critical level. Tanks should be punped out as soon as possible. <br /> 8 System is discharging to the surface. Tanks must be pumped out within 48 hours to eliminate surface dischar�e. <br /> 9 Inspection risers missing-tanks could not be inspected. Inspection risers (4" dia. pipe) must be installed tn each <br /> tank at next punpout. If tanks have not been punped out within the last three years, they should be punped <br /> out now. <br /> 10 Inspection pipe is lxated directly over tank baffle (does not give accurate measurement of solids accunulation). <br /> If tanks have not been punped out within thn iA�r *ti�ee ye_� they should be punped out now. <br /> ars �um o� <br /> DRAINFIELD CONDITION C11-14): <br /> Dr field inspection indicates: <br /> I1 Drainfield is dry, no surfacing evident. <br /> TZ Sane evidence of surfacing, not critical yet. <br /> 13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector <br /> immediately. Repeirs must be completed within 90 days. <br /> 14 Drainfield extent and condition unknown. <br /> LIMITING SITE FACTORS (sloae,setbacks.etc.): <br /> POTENTIAL FOR SYSTEM FAILURE (decends on soils.water table.etc.): ��'�G����� <br /> f <br /> COMMENTS: <br /> Date of Inspection Syste Inspector <br /> Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of <br /> property, be edvised that this report does not guarantee or cert�fy that an existing system will continue to function <br /> properly� but is merely en opim on of the adequacy of the system under current conditions based on the available <br /> information. <br /> This report must be kept on the premises with the system lxetion and punping records. <br /> WHITE COPY/Inspectors File YELLOW COPY/Homeowner <br />
The URL can be used to link to this page
Your browser does not support the video tag.