Laserfiche WebLink
� �� <br /> O : O <br /> -�����-=- CITY of ORONO <br /> , �,. �_ . <br /> '� '`f��'�r�� � ti M���� o��� <br /> ,�"�� `'.Ii::��� ,:i+�.=� G�, <br /> � '`"�.r-,;� . <br /> Street Address: °15a—a4q—�'16o O Mailing Address: <br /> '�'�gpg'� 2750 Kelley Parkway P.O. Box 66 <br /> Orono, MN 55356 Crystal Bay, MN 55323-0066 <br /> � /h;ilS o� ��/ <br /> To Currcnt Owner: �ddress: 1 � �' <br /> City Ordinance 199 requires that each existing on-site sewage treatment system in Orono be inspected every two years. <br /> The on-site sewage treatment system at the above address has been inspected and appears to fall into the categories checked below. <br /> SYSTEM CONFORMITY (1-3): � <br /> 1 "CODE SYSTEM"An LSTS which meets all the location,design and conshuction standards of�e current Orono Municipal Code. <br /> �2 `COMPLIANT SYSTEM" An ISTS which does not�et all the location,design and cons�uc6on standazds of the current Orono <br /> Municipal Code but dces meet the thrce foot separation require�►ent or two foot requirement for systems installed 1996 or earlier,and <br /> which is not failing or an i�inent threat to public health or safety. <br /> 3 "NON-COMPLIANT SYSTEM" A prohibited ISTS;an ISTS located within a designated 100-year flood plain,any LSTS which may <br /> or may not meet all the location,design,or construction stanc�rds of the current Orono Municipal Code and which is failing for any <br /> reason;and any ISTS with less than three feet of unsaturated soil or sand between the distribution device and the limiting soil characteristics. <br /> TANK CONDTI'ION(5-7): � <br /> Tank inspection indicates: <br /> 5 Pumpout not needed at this time. <br /> �eptic tanks must be pumped out this year (city code recommends tanks to be pumped out once every 3 years. <br /> Tank was last pumped ). <br /> Make sure seutic tanks are aumced throu¢h manhole and not throueh white insaection aiaes. T6is allows for the nrouer <br /> cleaninE. Keea water softner and iron filter dischar¢e out of seutic svstem to arolon¢life of drainfield. Ask uumaer to test <br /> alarm float to verifv alarm is still workin¢in vour house. The alarm warns owner t6at seataee is about to backua into basement <br /> 7 inspection risers missing-tanks could not be inspected. Inspection risers(4"dia.pipe)must be installed in each tank. If <br /> tanks have not been pumped out within the last three years,they should be pumped out now. <br /> DRAINFIELD CONDTTION 8-10 : � - <br /> Drainfield is dry,no surfacing evident. <br /> 9 Some evidence of surfacing,not critical yet. <br /> 10 Drainfield.is saturated and visibly discharging untreated ef�luent to the surface. Contact the City Inspector <br /> iminediately.Repairs must be completed within 90 days. <br /> COMMENTS: �«:��.��� 10�K S ��C _ v�� � S e� �,� }��1C� <br /> s� r- r—« o a S' _ <br /> �' -Z.b—D�, ��1'`�-u�-� <br /> Date of Inspection Matt Bolterman- Septic System Inspector <br /> Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or otha transfer of property,be advised that this report does <br /> not guarantee or certify that an existing system will continue to function properly, but is merely an opinion of the adequacy of the system under cumnt <br /> conditions based on the available information. <br />