Jeanne A. Mabusth, Zoning Administrator <br /> ' Re: Donald C. Mogen, 1170 Lyman Avenue <br /> April 12, 1983 <br /> Page 2 <br /> A number of deficien�ies- �re �no�ed iri"''t oposed septic <br /> system design: � <br /> Proposed - 2 tanks 1-900 gal 1-500 gal . <br /> ; <br /> Required - 2 tanks 1-1000 gal min 1-750 gal min <br /> '�� <br /> Proposed - 915 s. f. drainfield , <br /> � . Required - 330 s . f. per bedroom or 990 s . f. for <br /> a 3 bedroom home <br /> Proposed "levelling" at drainfield site is questionable and <br /> not advisable - drainfield site should remain undisturbed �^--� <br /> and drop boxes should be used. <br /> Finally, note that if a proposal for a specific house location <br /> would encroach on the tested drainfield sites , further <br /> testing would likely be required prior to approval of a �----�-�• <br /> building permit. <br />