My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2017-00531 (Septic)
Orono
>
Property Files
>
Street Address
>
A
>
Augusta Street
>
4730 Augusta Street - 06-117-23-32-0010
>
Septic
>
2017-00531 (Septic)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 5:26:45 PM
Creation date
6/6/2017 8:19:34 AM
Metadata
Fields
Template:
x Address Old
House Number
4730
Street Name
Augusta
Street Type
Street
Address
4730 Augusta St
Document Type
Septic
PIN
0611723320010
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
22
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
tnstat[er Summary <br /> 2250 gallon Septic tank(minimum) Tank options: none <br /> �vA►atger wnK wun rnuu�p►r cornpi ian�s <br /> 1300 gatlon Dose tank{minimum) at 25.49 gpi <br /> 36 GPM @ 16 ft. of head, Purr�p required <br /> 7.6 inch swing on Demand float which translates to roughty 4.8 inches of float tether length <br /> if tirr�dosi�is required --> 5.4 minutes ON time& Uhours OFF time <br /> 20 inches from bc�ttom of tank to"pump ON"ftoat,or 12 inches ta"timer ON"float <br /> 23 inches from bottom of tank to"Hi Levet Alarm"or 33 irtiches to'Hi level alarm"if tirt�e dosed <br /> 38 ft. ot 2.0 inch supply line with end feed manifotd connection <br /> (Tip:"top feed"manifold to conirol drainbackj <br /> 22 inch,or 1.8 ft. Sand Lift Mound <br /> 9.9 ft.wide by 63.0 ft. tong Rock bed <br /> 3 taterals 2.00 inch diameter G1.0 ft. tong 3.0 ft. laterat spdciru3 <br /> 7/32 iach perfs 3.0 ft. perforation spacing <br /> No Efftuent fitter fr alarm <br /> 3 clean out f�vaive box assemblies <br /> 26.8 ft.Total sand ABSORPTlON width (minimum) <br /> 0.0 ft. upstope and sideslope (sand 6eyond rockbed, minimum� <br /> i 6.9 ft. Downstope , __ - <br /> Specific stope ratios give BERM widths(topsoit beyond rockbed)of: <br /> 4:1 upslope ratio t 3 ft. upslope berm <br /> 3:1 sideslope 13 ft.sidestope berms <br /> 4:1 downstope 22 ft. downslope berm <br /> 4" inspection pipe <br /> 18"cover on top <br /> U si berm �3 pownsl berm 22 <br /> �/`� ._._�._._. __.....m,,� ___�__...�._�r.a. 12"cover on sides <br /> _._..._ ,., � _..,._,.....__._�__...._..: _ ..�.. (o"loe�aycap6c6'topsoil� <br /> 1.$ �l�r1ll S�3t;:1 l�ft <br /> 1.2 <br /> Absor tion Width t6.s _ _ _ <br /> Note: <br /> For 0 to 1�slopes, Absarptivn ys�id�h is me�sured from the Bea'equalty in both directions. <br /> For stopes >1�;, Absorption Width is meawred downhill from the upslope edge of the Berf <br /> Rock Bed: 21.0 Yd3 or'7.4= 29 ton 6 inches under pipe <br /> Mound Sand: 220 yd3 or't.4= 3pq ton catculatia►based on 3:1/4:1 stope from top of rockbe� <br /> Loamy Cap: 78 Yd3 or`1.4= 109 ton 6"deep <br /> Topsoil: 89 Yd3�'1.'�� 125 ton 6"deeP <br />