My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2017-00531 (Septic)
Orono
>
Property Files
>
Street Address
>
A
>
Augusta Street
>
4730 Augusta Street - 06-117-23-32-0010
>
Septic
>
2017-00531 (Septic)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 5:26:45 PM
Creation date
6/6/2017 8:19:34 AM
Metadata
Fields
Template:
x Address Old
House Number
4730
Street Name
Augusta
Street Type
Street
Address
4730 Augusta St
Document Type
Septic
PIN
0611723320010
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
22
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
tNSPECTOR CHECKLIST - mound <br /> 4/3U Auqusta Streei <br /> � V4'ELL se�backs: 20'to preswre tested sewer line (5 psi for 15 min) <br /> 50'to everything 100'to dispersat area with sha[tow rwell <br /> PROPERTI't_ItiES srttr�k: 10'to everything <br /> Roa.i secl+ack: platted: 10'prop tine. Metes&bounds:out of road easement, or outer ditch. <br /> LAiCE�BI.I�FF ,�iback: 20'fa-Wuff. Lakes:GD_, RO,, NE_.. Protected wetland_ <br /> Buiiding srtbacks: 10'for everything, ZO'for dispersat area. <br /> v1'ATFR LI�E un�r Prc-�sure�t0'to bed.tank&sevrer line. (etse sewer tine> 12"below) <br /> � Sewer tine�batfte connection (no 90's, 3'between 45's, stope min 1"in 8', max 2"in 8') <br /> (no depth req's, dean out every 100', Sch 4Q pipe) <br /> � Septic tank and risers (water tight, insulated, proper depth,existing verifietl by pumping} <br /> mfg 2250 gallons �one <br /> Riser over outlet, rise�over inEet or center, and 6"+inspecrion pipe over any remaining bafftes. <br /> No effluent fitter&atarm <br /> Dose tank risers and piping (water tight, insutated, proper depth,drainback) <br /> mf� 1300 gallons <br /> � dose pump 36 gpm 16 head VERIFY PUMP CURVE 5.4 min ON 9 hr OFF <br /> � ftoat setting drop 7.6 inches at 25.5 gpi "DESlGNED" 4.8 inches approx float tether length <br /> 194.0 gal dose divided by gpi "INSTALLED"= inches ftoat drop�field corrected <br /> LABEL pump requirements and drawdown on�ser or panel <br /> Cam lock reachabte from grade-3U'max. J-hook weep hole. Suppty tine access Ino hard 9Q'sy <br /> 2.0 inch wppty pipe: Sch40, stoped 1/8'+, supported by 4"sch40 steeve or compacted, and buried 6"*, <br /> spt�e box /control panet /etectrical connections <br /> ftow measurement: CT, ETM, time dosed, home water meter <br /> maund absorption area rough up <br /> mound rock dimensions 9.9 X 63.0 <br /> Sand lift depth 22 inches. (Jar test: 2"sand teaves< 118"silt after 30 min) <br /> � Absorption Sand beyond rock 0.0 upslope 16.9 downslope <br /> � Sermed topsoil beyond rockbed 13 upslope 13 sideslope 22 downstope <br /> caver depth of 12-t8"+ VERIFY <br /> 3 laterals (1-2'from edge of rock} <br /> 2.00 inch pipe size �Sch40 pipe 8 fittings► <br /> 3.0 ft lateral spacing <br /> 8 �t32 inch perforations <br /> 3.0 ft perforation spacing <br /> Air inlet ai end of laterats, and at top feed manifold if necessary. VERIFY <br /> ctean outs {no hard 90's) <br /> 4"inspection pipe to bottom of rock,anchored VERIFY <br /> Abandon existing system-if necrssary �Re•use existing tank certification <br /> monitoring ptan and type <br /> wett abandonment form - if necessary <br />