Laserfiche WebLink
tNSPECTOR CHECKLIST - mound <br /> 4/3U Auqusta Streei <br /> � V4'ELL se�backs: 20'to preswre tested sewer line (5 psi for 15 min) <br /> 50'to everything 100'to dispersat area with sha[tow rwell <br /> PROPERTI't_ItiES srttr�k: 10'to everything <br /> Roa.i secl+ack: platted: 10'prop tine. Metes&bounds:out of road easement, or outer ditch. <br /> LAiCE�BI.I�FF ,�iback: 20'fa-Wuff. Lakes:GD_, RO,, NE_.. Protected wetland_ <br /> Buiiding srtbacks: 10'for everything, ZO'for dispersat area. <br /> v1'ATFR LI�E un�r Prc-�sure�t0'to bed.tank&sevrer line. (etse sewer tine> 12"below) <br /> � Sewer tine�batfte connection (no 90's, 3'between 45's, stope min 1"in 8', max 2"in 8') <br /> (no depth req's, dean out every 100', Sch 4Q pipe) <br /> � Septic tank and risers (water tight, insulated, proper depth,existing verifietl by pumping} <br /> mfg 2250 gallons �one <br /> Riser over outlet, rise�over inEet or center, and 6"+inspecrion pipe over any remaining bafftes. <br /> No effluent fitter&atarm <br /> Dose tank risers and piping (water tight, insutated, proper depth,drainback) <br /> mf� 1300 gallons <br /> � dose pump 36 gpm 16 head VERIFY PUMP CURVE 5.4 min ON 9 hr OFF <br /> � ftoat setting drop 7.6 inches at 25.5 gpi "DESlGNED" 4.8 inches approx float tether length <br /> 194.0 gal dose divided by gpi "INSTALLED"= inches ftoat drop�field corrected <br /> LABEL pump requirements and drawdown on�ser or panel <br /> Cam lock reachabte from grade-3U'max. J-hook weep hole. Suppty tine access Ino hard 9Q'sy <br /> 2.0 inch wppty pipe: Sch40, stoped 1/8'+, supported by 4"sch40 steeve or compacted, and buried 6"*, <br /> spt�e box /control panet /etectrical connections <br /> ftow measurement: CT, ETM, time dosed, home water meter <br /> maund absorption area rough up <br /> mound rock dimensions 9.9 X 63.0 <br /> Sand lift depth 22 inches. (Jar test: 2"sand teaves< 118"silt after 30 min) <br /> � Absorption Sand beyond rock 0.0 upslope 16.9 downslope <br /> � Sermed topsoil beyond rockbed 13 upslope 13 sideslope 22 downstope <br /> caver depth of 12-t8"+ VERIFY <br /> 3 laterals (1-2'from edge of rock} <br /> 2.00 inch pipe size �Sch40 pipe 8 fittings► <br /> 3.0 ft lateral spacing <br /> 8 �t32 inch perforations <br /> 3.0 ft perforation spacing <br /> Air inlet ai end of laterats, and at top feed manifold if necessary. VERIFY <br /> ctean outs {no hard 90's) <br /> 4"inspection pipe to bottom of rock,anchored VERIFY <br /> Abandon existing system-if necrssary �Re•use existing tank certification <br /> monitoring ptan and type <br /> wett abandonment form - if necessary <br />