<br /> I Rhva R sec idential 8 Light Commercial HVAC Loads Elite Software Development,Inc '
<br /> Sabre Plumbing&Heating 1065 Linden Ln Orono'
<br /> �Plvmouth MN_55447 ___ � �__
<br /> - --- - --
<br /> -- -
<br /> - -- -
<br /> 'I '�_System 1 -Summary Loads =- _ __- - - - - -- - - - a e 4 ��
<br /> ' Com �ent , - - - - __- ---_ .---- ----- -- - Quan ---- Loss ___ Gain _ _ Gam -- _Gain
<br /> p Area Sen Lat Sen Total '
<br /> �, Descn tion
<br /> ' LOW EE: Glazing-Builder Grade Low E Wmdows& 1023 26,957 0 27,760 27,760
<br /> ; Sliding Door.33 U value .33 SHGC, u-value 0.31, '
<br /> SHGC 0.29 �
<br /> 11J: Door-Metal- Fiberglass Core 119.1 6,076 0 2,072 2,072 '
<br /> � 12E-Osw: Wall-Frame, R-19 insulation in 2 x 6 stud 5064 29,271 0 7,026 7,026
<br /> cavity, no board insulation, siding finish, wood studs
<br /> 1560-4sf-4: Wall-Basement, , R-4 board insulation to 316.7 2,422 0 0 0 �
<br /> , floor, no interior finish, 4'floor depth
<br /> 15B0-4sf-8: Wall-Basement, , R-4 board insulation to 1428 9,981 0 407 407 I
<br /> floor, no interior finish, 8'floor depth
<br /> j 17C-0: Roof/Ceiling-Roof Deck(roofing, wood, insulation) 200 4,880 0 2,354 2,354 �I
<br /> or SIP Panels Supported on Beams, White or Light �
<br /> Color Tile, Slate or Concrete, White Metal, White ;
<br /> Membrane, 1.5"wood, no insulation '
<br /> 166-44: Roof/Ceiling-Under Attic with Insulation on Attic 442.9 828 0 516 516
<br /> Floor(also use for Knee Walls and Partition ;
<br /> � Ceilings), Vented Attic, No Radiant Barrier, Dark '�
<br /> Asphalt Shingles or Dark Metal, Tar and Gravel or
<br /> Membrane, R-44 insulation ;
<br /> 21A-20: Floor-Basement, Concrete slab, any thickness, 2 3252.7 7,465 0 0 0 �I
<br /> or more feet below grade, no insulation below floor, !
<br /> any floor cover, shortest side of floor slab is 20'wide
<br /> ; 20P-38: Floor-Over open crawl space or garage, Passive, 442.9 1,129 0 173 173 I
<br /> ' R-38 blanket insulation,any cover �
<br /> I
<br /> Subtotals for structure: 89,009 0 40,308 40,308
<br /> i People: 0 0 0 0 �
<br /> Equipment: 1,041 6,932 7,973 �
<br /> Lighting: 0 0 0
<br /> � Ductwork: 5,214 769 1,361 2,130
<br /> I Infiltration: Winter CFM: 296, Summer CFM: 198 26,884 5,015 3,803 8,818 i
<br /> Ventilation: Winter CFM: 0, Summer CFM: 0 0 0 0 0 �
<br /> Exhaust: Winter CFM: 140, Summer CFM: 140
<br /> Humidification (Winter) 12.69 gal/day : 4,655 0 0 0 I
<br /> AED Excursion: 0 0 3,566 3,566 ��
<br /> �� System 1 Load Totals: 125,763 6,825 55,970 62,795
<br /> � Check Fi ures
<br /> i ,,
<br /> � Supply CFM: 2,622 CFM Per Square ft.: 0.347
<br /> I Square ft. of Room Area: 7,563 Square ft. Per Ton: 1,445
<br /> Volume(ft3)of Cond. Space: 71,315
<br /> � �Svstem Loads � ��i
<br /> �j Total Heating Required Including Ventilation Air: 125,763 Btuh 125.763 MBH '
<br /> �, Total Sensible Gain: 55,970 Btuh 89 % ,
<br /> I Total Latent Gain: 6,825 Btuh 11 % �
<br /> ; Total Cooling Required Including Ventilation Air_ 62,795 Btuh 5.23 Tons(Based On Sensible + Latent)
<br /> � Notes
<br /> �I Rhvac is an ACCA approved Manual J and Manual D computer program.
<br /> ' Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D.
<br /> � All computed results are estimates as building use and weather may vary.
<br /> Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at
<br /> your design conditions. '�I
<br /> � I
<br /> - - �
<br /> C:\ ...\Swanson 1065 Linden Ln Orono KUZNIK.rh9 Thursday, December 12, 2013, 12:49 PM