I Rhvac-Residential 8�Light Commercial HVAC Loads Elite Software Development,Inc.�'
<br /> I Sabre Piumbing&Heating 1065 Linden Ln Orono
<br /> I Plymouth MN 55447_________
<br /> ------ - ----- -- _ _._ -- - Pa�e 3�
<br /> � - -_ _ -- -- --- - - --- - - --. ---- --- --- - - ----- --
<br /> ' j Load Preview Report ,
<br /> ; ;
<br /> � Sys; Sys; Sys`
<br /> Net'�, ft.�l, Sen Lat' Net` Sen; � Duct
<br /> Scope Ton /Ton, Area! Gain' Gam'', Gain; Lossi Htg Cig' Act� Size
<br /> CFM: CFMi CFM�
<br /> _______�, _....___.. .__._._ _ . ._. _ ;�____ __ _:._._._ ___._,__.--..__.
<br /> -- ---.___.. . .__- __.__.._..._ __._____----_ __ ____. _....._.__
<br /> Building 5.23 1,445 7,563 55,970 6,825 62,795 125,763 1,683 2,622 2,622
<br /> System 1 5.23 1,445 7,563 55,970 6,825 62,795 125,763 1,683 2,622 2,622 22x22
<br /> Duct Latent 769 769
<br /> H um id ification 4,655
<br /> Zone 1-Clg.:31%,Htg.:38% 3,253 21,110 1,494 22,604 46,274 643 989 989 12x15
<br /> 1-Basement 3,253 21,110 1,494 22,604 46,274 643 989 989 9--6
<br /> Zone 2-Clg.:56%,Htg.:42% 3,253 38,421 3,103 41,524 50,840 707 1,800 1,800 18x18
<br /> 2-Main Floor 3,253 38,421 3,103 41,524 50,840 707 1,800 1,800 17--6
<br /> Zone 3-Clg.:6%,Htg.:9% 443 4,350 589 4,939 10,893 151 204 204 6x6
<br /> 3-Bonus Room 443 4,350 589 4,939 10,893 151 204 204 2--6
<br /> Zone 4-Clg.:8%,Htg.:11% 614 5,300 870 6,170 13,100 182 248 248 7x7
<br /> 4-2nd floor 614 5,300 870 6,170 13,100 182 248 248 3--5
<br /> Sum of room airflows may be greater than system airflow because
<br /> s stem has multi le zones.
<br /> C:\...\Swanson 1065 Linden Ln Orono KUZNIK.rh9 Thursday, December 12, 2013, 12:49 PM