My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2017-00341 - septic
Orono
>
Property Files
>
Street Address
>
L
>
Lakeview Parkway
>
780 Lakeview Parkway - 06-117-23-43-0021
>
Septic
>
2017-00341 - septic
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 5:29:12 PM
Creation date
5/4/2017 10:55:51 AM
Metadata
Fields
Template:
x Address Old
House Number
780
Street Name
Lakeview
Street Type
Parkway
Address
780 Lakeview Pkwy
Document Type
Septic
PIN
0611723430021
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
21
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Installer Summary <br /> � 2250 galton Septic tank (minimum) Tank options: none <br /> �un,�arger ianK wi�n rnuiupie c.oni�i�anK� <br /> 1300 gallon Dose tank (minimumj at 25.49 gpi <br /> 36 GPM C 19 ft. of head, Pump required <br /> 7.9 inch swing on Demand float which translates to roughty 5.0 inches of float tether tength <br /> if time dosing is required --> 5.6 minutes ON time£t �hours OFF time <br /> 20 inches from bottom of tank to"pump ON"ftoat> or 12 inches to'"timer ON"float <br /> 23 inches from bottom of tank to"Hi Levet Aiarm"or 33 inches to"Hi tevel alarm"if time dosed <br /> 85 ft. of 2.0 inch suppty line with end feed manifold connection <br /> (Tip: "top feed"manifold to controt drainback) <br /> 14 inch, or 1.2 ft. Sand Lift Mound <br /> 10.0 ft. wide by 63.0 ft. long Rock bed <br /> 3 taterats 2.00 inch diameter 61.0 ft. long 3.0 ft. lateral spacing <br /> 7/32 inch perfs 3.0 ft. perforation spacing <br /> No Efftuent fitter E�alarm <br /> 3 ctean out&valve box assembties <br /> 27.0 ft.Totat sand ABSORPTION width (minimum) <br /> 0.0 ft. upslope and sideslope (sand beyond rockbed, minimum) <br /> 17.0 ft. Downstope isand beyor,L rockbed, ,r�in����,m� <br /> Specific slope ratios give BERM widths (topsoil beyond rockbed)of: <br /> 4:1 upstope ratio 9 ft. upslope berm <br /> 3:1 sideslope 13 ft. sidestope berms <br /> 3:1 downslope 21 ft. downstope berm <br /> 4" inspection pipe <br /> 18" cover on top <br /> U slo e berrn 0 Downslo berm Z� <br /> 12" cover an sides <br /> , (6"loamy cap&6"topsoil} <br /> 1.2 Clecsn ���;td i;ft <br /> --- <br /> 1.8 ��� � ~��. <br /> € -,,. __,.. � <br /> ,,��t ��c� �;;;� u t�;�� � � _ _ <br /> Absor tion Width 27•0 <br /> Note: <br /> _._.______.. <br /> For 0 Ea 1�;stopes, Abso�ption width is measured from Che Bedequatty in both directions. <br /> For stopes >1�, .4bsorption Width is measured downhiU from the upslope edge of the Bed. <br /> Rock Bed: 21.0 yd3 or"1.4= 29 ton 6 inches under pipe <br /> Mound Sand: 164 yd3 or"1.4= 229 ton calcutation based on 3:1/4:1 slope from top of rockbe� <br /> Loamy Cap: 68 yd3 or•1,4= 95 ton 6"deep <br /> Topsoil: gp yd3 or�1.4= 112 ton 6"deep <br />
The URL can be used to link to this page
Your browser does not support the video tag.