Laserfiche WebLink
INSPECTOR CHECKLIST - mound <br /> /LS Lakeview Narkway <br /> � WEI.L setbac{:s: 20'to pressure tested sewer line (5 psi for 15 min► <br /> 50'to everything 100'to dispersal area with shallow welt <br /> PRUPERTY LINES seiba�:k: 10'to everything <br /> Roed se[back: platted: 10'prop line. Metes&bounds:out of road easement,or outer ditch. <br /> LAKF,r BLUFF srrback: 20'for bluff. Lakes:GD_,RD_,NE_. Protected wetland <br /> Building setbacks: 10'for everything, 20'for dispersal area. <br /> WA"fER LINE under pressure sc 10'to bed,tank&sewer line. (else sewer line� 12"betow) <br /> � Sewer line&baffte connection (no 90's, 3'between 45's, slope min t"in 8',max 2"in 8') <br /> (no depth req's, clean out every tOQ', Sch 40 pipe� <br /> � Septic tank and risers (water tight,insulated,proper depth,existing verified by pumping) <br /> mf8 2250 gallons none <br /> Riser over outtet, riser over inlet or center,and 6"+inspection pipe over any remaining baffles. <br /> No effluent filter&alarm <br /> Dose tank risers and piping (water tight,insutated,proper depth,drainback) <br /> mfg 1300 gatlons <br /> � dose pump 36 gpm 26 head VERIFY PUMP CURVE 5.9 min oN 9 hr OFF <br /> � float setting drop 8.7 inches at 24.5 gpi "DESIGNED" 5.4 inches approx float tether length <br /> 212.0 gal dose divided by gpi "INSTALLED"� inches float drop(field corrected <br /> LABEL pump requirements and drawdown on riser or panel <br /> Gam lock reachable from grade-30"max. J-hook weep hole. Supply line access (no hard 40's) <br /> 2.0 inch supply pipe:Sch40, sloped t/8"+, supported by 4"sch40 sleeve or compacted, and buried 6"f. <br /> sptice box/control panel/electrical connections <br /> ftow measurement:CT,ETM,time dosed,home water meter <br /> mound absorption area rough up <br /> mound rock dimensions 10.0 X 63.0 <br /> Sand llft depth 20 inches. (Jar test:2"sand teaves< 1/8"sitt after 30 min) <br /> � Absorption Sand beyond rock 0.0 upslope 10.0 downslope <br /> � Bermed topspit beyond rakbed t t upslope 13 sideslope 22 downslope <br /> cover depth of 12-18"+ VERIFY <br /> 3 laterels (t-2'from edge of rock) <br /> 2.00 inch pipe size (Sch40 pipe f�fittings) <br /> 3.0 ftlateratspacing <br /> 8 7/32 inch pertorations <br /> 3.0 ft perforation spacing <br /> Air inlet at end of laterals, and at top feed manifold if necessary. VERIF7 <br /> ctean outs (no hard 90's) <br /> 4"inspection pipe to bottom of rock,anchored VERIFY <br /> Abandon existing system-if necessary �Re-use existing tank certification <br /> moNtoring ptan and type <br /> well abandonment form •if necessary <br />