My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
septic design-general approval
Orono
>
Property Files
>
Street Address
>
L
>
Lakeview Parkway
>
725 Lakeview Parkway - 06-117-23-34-0008
>
Septic
>
septic design-general approval
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 5:27:29 PM
Creation date
4/19/2017 1:17:50 PM
Metadata
Fields
Template:
x Address Old
House Number
725
Street Name
Lakeview
Street Type
Parkway
Address
725 Lakeview Pkwy
Document Type
Septic
PIN
0611723340008
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
13
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Installer Summary <br /> 2250 gallon Septic tank(minimum) Tank options: none <br /> xrA�arsler �anK wnn rnuuipie cvrnpi�a�n� <br /> 1300 gatlon Dose tank(minimum) at 24.49 gpi <br /> 36 GPM(� 26 ft. of head, Pump required <br /> 8.7 inch swing on Demand float which translates to roughly 5.4 inches of float tether length <br /> if time dosing is required•-> 5.9 minutes ON time& �hours OFF time <br /> 21 inches from bottom of tank to`pump ON"ftoat,ar 12 inches to'timer ON"ftoat <br /> 24 inches from bottom of tank to"Hi Level Atarm'or 34 inches to"Hi level atarm"if time dosed <br /> 142 ft, of 2.0 inch supply line with end feed manifotd cannection <br /> (Tip:"top feed"manifold to control drainback) <br /> 20 inch,or 1.7 ft. Sand lift Mound <br /> 10.Q ft.wide by 63.0 ft. long Rxk bed <br /> 3 laterals 2.00 inch diameter 61.0 ft. long 3.0 ft. lateralspacing <br /> 7/32 Inch perts 3.0 ft. perforation spacing <br /> No Effluent fllter 8 alarm <br /> 3 clean out 8 valve box assembties <br /> 20.0 ft.Total sand ABSORPTION width �minimum) <br /> 0.0 ft.upslope and sideslope (sand beyond rockbed,minimum) <br /> 10.0 ft.Downslope tsand beyond rockbed, minimumi <br /> Specific stope ratios give BERM widths(topsoil beyond rockbed)of: <br /> 4:1 upslope ratio 11 ft.upstope berm <br /> 3:1 sideslope 13 ft.sideslope berms <br /> 3:1 downslope 22 ft.downslope berm <br /> 4"inspection pipe <br /> 18"cover on top <br /> U o berm �� Dawnst berm 2t <br /> -12"cover on sides <br /> {6"loemy cap dc 6"toPaoin <br /> 1.7 Ctean sand lift <br /> . 1_3 De�th ::> '_init�n� <br /> Limit������ond�[ion - - -_ - -- - --- --.- <br /> Absor tion Width zo.0 _ __ _. .._ _ . <br /> Note• <br /> For 0 to 1%stopes,,4ascv�ptton Nrydth is meawred from the Bedequalty in both directions. <br /> For slopes>1%, .4bsorptlon H�dth is measured downMll from the upstope edge of the Bed. <br /> Rock Bed: 21,p yd;or`1.4= 29 ton 6 inches under pipe <br /> Mound Sand: 200 yd'or`1.4= 280 ton catculation based on 3:7/4:1 slope from top of rockbe� <br /> Loamy Cap: 74 yd3 or"1.4= 104 ton 6"deep <br /> Topsoil: 86 yd;or•1.4= 120 ton 6"deep <br />