Laserfiche WebLink
r � <br /> Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc. <br /> Sabre Plumbinq&Heatinq � 195 Kintyre Ln Orono <br /> Plymouth MN 55447 Page 4 <br /> System 1 Summary Loads <br /> Component Area Sen Lat Sen Total <br /> Description Quan Loss Gain Gain Gain <br /> LOW EE: Glazing-Builder Grade Low E Windows& 686.7 18,094 0 18,279 18,279 <br /> Sliding Door.33 U value .33 SHGC, u-value 0.31, <br /> SHGC 0.29 <br /> 11J: Door-Metal- Fiberglass Core 61.8 3,151 0 1,075 1,075 <br /> EXT R-5-9': Wall-Basement, Custom, Rigid R-5 Styro- 1166 19,823 0 0 0 <br /> foam to top of footing- EXTERIOR PERIMETER-9' <br /> basement <br /> 12E-Obw: Wall-Frame, R-19 insulation in 2 x 6 stud 1214 7,017 0 1,189 1,189 <br /> cavity, no board insulation, brick finish,wood studs <br /> 12E-Osw: Wall-Frame, R-19 insulation in 2 x 6 stud 3587 20,733 0 4,976 4,976 <br /> cavity, no board insulation, siding finish,wood studs <br /> RJ 10 Spray Foam: Wall-Frame, Custom, Closed Cell 680.7 5,789 0 1,846 1,846 <br /> R10 Spray Foam <br /> .15B0-5sf-8: Wall-Basement, , R-5 board exterior 832 5,092 0 0 0 <br /> insulation to footing, no interior finish, 8'floor depth <br /> 16B-44: Roof/Ceiling-Under Attic with Insulation on Attic 3108.6 5,813 0 3,625 3,625 <br /> Floor(also use for Knee Walls and Partition <br /> Ceilings), Vented Attic, No Radiant Barrier, Dark <br /> Asphalt Shingles or Dark Metal, Tar and Gravel or <br /> Membrane, R-44 insulation <br /> 21A-32: Floor-Basement, Concrete slab, any thickness, 2 1747.8 2,971 0 0 0 <br /> or more feet below grade, no insulation below floor, <br /> any floor cover, shortest side of floor slab is 32'wide <br /> 21A-28: Floor-Basement, Concrete slab, any thickness, 2 813.8 1,522 0 0 0 <br /> or more feet below grade, no insulation below floor, <br /> any floor cover, shortest side of floor slab is 28'wide <br /> 20P-30: Floor-Over open crawl space or garage, Passive, 186.2 553 0 85 85 <br /> R-30 blanket insulation, any cover <br /> 20P-38: Floor-Over open crawl space or garage, Passive, 410.7 1,047 0 160 160 <br /> R-38 blanket insulation,any cover_ _ <br /> Subtotals for structure: 91,605 0 31,235 31,235 <br /> People: 6 1,200 1,380 2,580 <br /> Equipment: 683 3,430 4,113 <br /> Lighting: 0 0 0 <br /> Ductwork: 5,258 1,447 1,614 3,062 <br /> Infiltration: Winter CFM: 166, Summer CFM: 0 15,072 0 0 0 <br /> Ventilation: Winter CFM: 140, Summer CFM: 140 5,080 3,547 1,076 4,623 <br /> AED Excursion: 0 0 702 702 <br /> System 1 Load Totals: 117,015 6,877 39,437 46,314 <br /> Check Fi ures <br /> Supply CFM: 1,797 CFM Per Square ft.: 0.272 <br /> Square ft. of Room Area: 6,605 Square ft. Per Ton: 1,711 <br /> Volume (ft') of Cond. Space: 68,510 <br /> S stem Loads <br /> Total Heating Required Including Ventilation Air: 117,015 Btuh 117.015 MBH <br /> Total Sensible Gain: 39,437 Btuh 85 % <br /> Total Latent Gain: 6,877 Btuh 15 % <br /> Total Cooling Required Including Ventilation Air: 46,314 Btuh 3.86 Tons (Based On Sensible+ Latent) <br /> Notes <br /> Rhvac is an ACCA approved Manual J and Manual D computer program. <br /> Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. <br /> All computed results are estimates as building use and weather may vary. <br /> Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at <br /> your design conditions. <br /> C:\...\Gonyea 195 Kintrye Ln Orono SIMPSON.rh9 Monday, June 30, 2014, 10:56 AM <br />