Laserfiche WebLink
1 � <br /> _ ��SimplEx nnu�t�-Applica#ion Peripherats <br /> UL, ULC, CSFM Listed;FMApproved; IDNetT"" and MAPNET II� Communicating Devices, <br /> • MEA (NYC) Acceptance* fndividual Addressable Modules (IAMs) <br /> � <br /> tDNet or MAPNET II addressable communications W <br /> supply both data and power over a single wire pair s:��f,r��R� <br /> to provide**: E�se-sooi�E�' <br /> �t�f�Si@ i�M � <br /> • Supervised Class B monitoring of normally open,dry �m.E�it.s�E-;�; <br /> contacts �arE cca�: <br /> � ,,;� �. ,3 <br /> • Total wiring distance from IAM to supervision <br /> resistor(s)ofup to 500 ft(152 m) t poGp���p <br /> • Monitored connection is compatible with Simplex� <br /> 2081-9044 Overvoltage Protectors for outdoor wiring or <br /> elechically noisy applications `�409Q-9001 Supervised IAM <br /> • For use in indoor locations up to 158°F(70°C)such as (shown approximately 314 size) <br /> attic spaces or similar applications <br /> For use with fotlowing Simplex control panels: <br /> • Model Series 4008,4010,401 OES,4100U and 4100ES <br /> fire alarm control panels for IDNet communications <br /> • Model Series 4100/4100U/4100ES,4120,4020,and <br /> 2I20 Communicating Device Transponders(CDTs) <br /> equipped with MAPNET II communications <br /> Mode1 4090-9001: <br /> • Enclosed design min.imizes dust infiliration ^ <br /> _ • Mounts in standard single gang electrical box �`�° <br /> �,�.°� <br /> • Screw terminals for wiring connections <br /> • Visible LED flashes to indicate communications <br /> ' • Optional covers are available to allow LED to be 4090-9051 Supervised IAM <br /> viewed after installation(requires mounting bracket, {shown approximately 3/4 size) <br /> ordered separately) <br /> Model 4090-9051: <br /> • Encapsulated design for extended exposure to high <br /> humidity(LED is not present on this model) � � � <br /> • Color coded 18 AWG leads for wiring Individual addressable modules (tAMs)receive <br /> IDNet communications provides current limited both power and communications from a two-wire <br /> monitoring: MAPNET II or IDNet circuit.They provide location <br /> Provides monitoring of tamper switch(supervisory) specific addressability to a single initiating deviee(such <br /> • and waterflow switch(alann)on same circuit using as single station smoke detector alarm contacts or heat <br /> detector contacts)or mulripte devices at the same locarion <br /> one point by monitoring nornially open dry contacts and the wiring <br /> • Available with IDNet communications only to an end-of-line resistor. <br /> Muitiple operation modes are avaitable and are <br /> selectable at the control panel: Model 4090-9001 is packaged in a tt,ermoplasric <br /> Contact closure status can be tracked housing and provides screw terminal connections and a <br /> ' status indicating LED. <br /> • Momentary contact closure conditions can be selected at <br /> the panel to be l.atched or tracked(not available with the Model 4090-9051 is an encapsulated package with wire <br /> 2120 CDT) leads.It does not provide a status indicating LED. <br /> UL listed to Standard 864 <br /> ' These produds have been approved by ihe Calit�nia State Fre Marshal(CSFM)pursuarri <br /> to Section 13144.t of fhe Cal'rfomia Health and Safety Code.See CSFM Listing <br /> 7300-0026:223 for allowable values ardlor corxiitiau conceming material presented in tlas <br /> document It is subject to re-examination,revision,and possible cancella6on.Accepted for <br /> use—City of New Yaic Departrnent of Buildings—MEA35-93E.Add'�lia�al listings may be <br /> _ applicable;contact your local Simplex product suppli�for the latest status.Lis6ngs and <br /> approvals under Simplex Time Recader Co.are ttie property of Tyco Safety Products <br /> Westrninster. <br /> 54090-0001-10 <br />