A non-structural steel special inspection final report-2015
Orono
>
Property Files
>
Street Address
>
K
>
Kelley Parkway
>
2730 Kelley Parkway - 33-118-23-12-0007
>
Misc
>
A non-structural steel special inspection final report-2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:45:43 PM
Creation date
3/28/2017 11:58:14 AM
Metadata
Fields
Template:
x Address Old
House Number
2700
Street Name
Kelley
Street Type
Parkway
Address
2700 Kelley Parkway
Document Type
Misc
PIN
3311823120007
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
41
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
I Page 1 of 1 <br /> s Rau N <br /> INTERTEC <br /> Special Inspection Daily Report <br /> City of Orono Page: 1 of 1 <br /> Report No.: #25 Date: October 10,2014 <br /> Project Name: Orono Police Dept.Expansion Project No: 614-05902 <br /> Projecf Address: 2730 Kelly Pkwy. 8raun Intertec PM: MARK FLYNN <br /> Clie►�t: Ci1y of Orono Cllent ProJect No.: <br /> Weather. Partly Cloudy Temperafure: 50°F <br /> Type of Inspection: Inspection Coverage: <br /> ❑Continuous ❑Masonry � Rebar Placement ❑ Foundations ❑Special Cases <br /> � Periodic ❑Welding&Bolting ❑Concrete ❑ Fireproofing <br /> ❑ Piles&Piers ❑Tendon Placement ❑Soils <br /> Did the architect or engineer authorize changes to approved plans2 Yes❑ (Listed Below) No � <br /> Descripfion and location of work complet�d: <br /> -Observed the plqcement of rebar for interior slab on grade @ Grid A to E from 1 to 6. <br /> -Picked up grout samples cast on 10-9-14. <br /> I <br /> Llst tests performad: <br /> I <br /> • Are there any discrepancies noted from this day's observations� Yes ❑ No � <br /> • Are there any outstanding discrepancfes on this project� Yes ❑ No � <br /> • If yes,see attached Summary Sheet. <br /> • Report Discussed with and Given to Contractor: Yes � No ❑ <br /> Report Emailed to: <br /> Jack Bronc.ryk jar:k.broncrykCg-krausanderson.com <br /> To the best of our knowledge,work inspected was done in accordance with the approved plans,speclfications and <br /> applicable workmanship provisions of the current IBC,except as noted above. <br /> -�;%� Loosbrock, Tom <br /> L?h /�/,/� <br /> I.D.No.: 1 136593 <br /> Prouiding engineering and ettuironmental solutions since 1957 <br />