Laserfiche WebLink
� O <br /> O O <br /> �����) CITY of ORONO <br /> � 'I4��}y �� �% � . <br /> ,\"�" ,�,� �:,� ;F-�`'.:;���' ��C„ Municipal Offices <br /> � ` <br /> �`��, M'��.;%.rY �^� � � SVeet Address: �lSa-a49'y6o 0 Mailing Addre s: <br /> ',�'`� � �`t `, � � 2750 Kelley Pa�kway P.O. Box 66 <br /> �-E$x� Orono, MN 55356 Crystal Bay, MN 55323-0066 <br /> To Current Owner: Address: SS A <br /> City Ordinance 199 requi es that each existing on-site sewage treatment system in Orono be inspected every two year . <br /> The on-site sewage trea nt system at the above address has been inspected and appears to fall into the categories c ecked below. <br /> SYSTEM CONFORI�IITY (1-3): � <br /> 1 "CODE SYSTEI�1"An LSTS which meets all the location,design and construcrion standards of the current Orono Municipal ode. <br /> 2 "CONIPLIANT�YSTEM" An ISTS which�es not meet all the location,design and consiruction standards of the current ono <br /> Municipal Code but does meet the three foot separation requirement or two foot requirement for systems installed 1996 ar earlier and <br /> which is not failing�r an imminent threat to public health or safety. <br /> 3 "NON-COMPL T SYSTEM" A prohibited ISTS;an ISTS located within a designated 100-year flood plain,any ISTS 'ch may <br /> or may not meet all e location,design,or construction standards of the current Orono Municipal Code and which is failing for y <br /> reason;and any ISTS wi less than Uuce feet of unsaturated soil or sand between the distribution device and the limiting soil charact s6cs. <br /> TANK CONDITION(�-7): � <br /> Tank inspection indica es: <br /> 5 Pumpout not nee ed at this time. <br /> 6 Septic tanks must e pumped out this year (city code recommends tanks to be pumped out once every 3 yeazs <br /> Tank was last p ped ). <br /> Make sure se tic tan are um ed throu h manhole and not throu h white ins ection i es. TLis aliows for the r er <br /> cleanin . Kee water softner and iron filter dischar e out of se tic s stem to rolon life of drainfield. Ask um e to test <br /> alarm float to veri ala m is still workin in our house. The alarm warns owner t6at se ta e is a6out to backu int basement. <br /> 7 Inspection risers issing-tanks could not be inspected. Inspection risers(4"dia.pipe)must be installed in ch tank. If <br /> tanks have not bee pumped out within the last three years,they should be pumped out now. <br /> DRAINFIELD CONDI ON�-10 : � <br /> 8 Drainfield is dry, o surfacing evident. <br /> 9 Some evidence o surfacing,not critical yet. <br /> 10 Drainfield is satu ted and visibly discharging untreated effluent to the surface. Contact the City Inspector <br /> immediately.Repa rs must be completed within 4U days. <br /> COMMENTS: <br /> S -a�- -c�S- 1.,�° (�' <br /> Date of Inspec ion Septic System Inspector <br /> I <br /> Note: In the event that this ins ection report is used to satisfy the requirements for a mortgage or other transfer of property,be advised that this report does <br /> not euarantee or certifv that �existin�system wil] continue to function properly, but is merely an opinion of the adequacy of the stem under current <br />