<br /> • Golden Vallle MNC5542 937 oommercial HVAC Loads Elite Software DeeeRu�n RPa�e 3 '
<br /> __ _ ---- - -- - _ -- - --- ---- - _ - - - -- ---- -
<br /> . - - -- - _ _ __
<br /> Tota! Buildin�_Summary Loads_ _
<br /> � ,_- - - - - --- _ - -
<br /> - --- ---- --------- - - --- ---- - --- - - - ------ - ---- --
<br /> Component Area Sen Lat Sen Total '�
<br /> Description Quan Loss Gain Gain Gain i
<br /> -- ------------ -------- ------ -- -
<br /> 2A-v-o: Glazing-Double pane low-e (e = 0.60), operable 199 6,129 0 7,343 7,343 ��
<br /> window, vinyl frame, outdoor insect screen with 50%
<br /> coverage, u-value 0.35, SHGC 0.36
<br /> � 11 N: Door-Metal - Polystyrene Core 78 2,402 0 874 874
<br /> �'� 15A-15sfoc-4: Wall-Basement, concrete block wall, R-15 458 1,829 0 90 90
<br /> � foam board to floor, no framing, no interior finish, I
<br /> open core, 4'floor depth
<br /> 12F1-Osw: Wall-Frame, R-21 open cell 1/2 Ib. spray foam 165 943 0 229 229
<br /> ', insulation in 2 x 6 stud cavity, no board insulation, �
<br /> siding finish, wood studs
<br /> 15A-15sfoc-8: Wall-Basement, concrete block wall, R-15 218 691 0 0 0
<br /> foam board to floor, no framing, no interior finish, �
<br /> open core, 8'floor depth
<br /> 12F-Osw: Wall-Frame, R-21 insulation in 2 x 6 stud 1208 6,909 0 1,672 1,672 I
<br /> cavity, no board insulation, siding finish, wood studs '
<br /> 16B-50: Roof/Ceiling-Under Attic with Insulation on Attic 979 1,723 0 1,096 1,096 I
<br /> Floor(also use for Knee Walls and Partition
<br /> '�, Ceilings), Vented Attic, No Radiant Barrier, Dark
<br /> �� Asphalt Shingles or Dark Metal, Tar and Gravel or
<br /> Membrane, R-50 insulation
<br /> ', 21A-20: Floor-Basement, Concrete slab, any thickness, 2 979 2,326 0 0 0
<br /> or more feet below grade, no insulation below floor, �I
<br /> any floor cover, shortest side of floor slab is 20'wide ��
<br /> �
<br /> Subtotals for structure: 22,952 0 11,304 11,304 �
<br /> � People: 2 400 460 860
<br /> '�, Equipment: 0 956 956 ;
<br /> , Lighting: 0 0 0
<br /> Ductwork: 0 0 0 0
<br /> Infiltration: Winter CFM: 93, Summer CFM: 50 8,709 716 1,110 1,826
<br /> Ventilation: Winter CFM: 40, Summer CFM: 40 789 578 188 767
<br /> Exhaust: Winter CFM: 50, Summer CFM: 50
<br /> AED Excursion: 0 0 3,512 3,512
<br /> Total Building Load Totals: 32,450 1,694 17,530 19,224 i
<br /> ' Check Figures ------ - ------- --- ----------------- -- J ��
<br /> Total Building Supply CFM: 812 CFM Per Square ft.: 0.415 �,
<br /> Square ft. of Room Area: 1,958 Square ft. Per Ton: 1,222
<br /> Volume (ft3)of Cond. Space: 20,070
<br /> -------------
<br /> ------------ -------------- --
<br /> Building Loads - -- - --- �
<br /> Total Heating Required Including Ventilation Air: 32,450 Btuh 32.450 MBH
<br /> , Total Sensible Gain: 17,530 Btuh 91 %
<br /> Total Latent Gain: 1,694 Btuh 9 %
<br /> Total Cooling Required Including Ventilation Air: 19,224 Btuh 1.60 Tons (Based On Sensible + Latent)
<br /> - _-- -
<br /> -- - _ _ _ -- -
<br /> _ ____-
<br /> Notes - --------- _-------
<br /> - - - - --- �
<br /> Rhvac is an ACCA approved Manual J and Manual D computer program.
<br /> Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D.
<br /> , All computed results are estimates as building use and weather may vary.
<br /> Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at
<br /> � your design conditions. �
<br /> �
<br /> L - - ----- ----------- --- - -------____J
<br /> \\flaresbs\company ...\Nor-Son Construction, Deer Run Remodel.rh9 Thursday, January 12, 2017, 8:28 AM