Laserfiche WebLink
. <br /> . __� _ , , -__ _ _ - - - - -- - _ - , <br /> � <br /> • Golden Vallle MNC5542 937 oommercial HVAC Loads Elite Software DeeeRu�n RPa�e 3 ' <br /> __ _ ---- - -- - _ -- - --- ---- - _ - - - -- ---- - <br /> . - - -- - _ _ __ <br /> Tota! Buildin�_Summary Loads_ _ <br /> � ,_- - - - - --- _ - - <br /> - --- ---- --------- - - --- ---- - --- - - - ------ - ---- -- <br /> Component Area Sen Lat Sen Total '� <br /> Description Quan Loss Gain Gain Gain i <br /> -- ------------ -------- ------ -- - <br /> 2A-v-o: Glazing-Double pane low-e (e = 0.60), operable 199 6,129 0 7,343 7,343 �� <br /> window, vinyl frame, outdoor insect screen with 50% <br /> coverage, u-value 0.35, SHGC 0.36 <br /> � 11 N: Door-Metal - Polystyrene Core 78 2,402 0 874 874 <br /> �'� 15A-15sfoc-4: Wall-Basement, concrete block wall, R-15 458 1,829 0 90 90 <br /> � foam board to floor, no framing, no interior finish, I <br /> open core, 4'floor depth <br /> 12F1-Osw: Wall-Frame, R-21 open cell 1/2 Ib. spray foam 165 943 0 229 229 <br /> ', insulation in 2 x 6 stud cavity, no board insulation, � <br /> siding finish, wood studs <br /> 15A-15sfoc-8: Wall-Basement, concrete block wall, R-15 218 691 0 0 0 <br /> foam board to floor, no framing, no interior finish, � <br /> open core, 8'floor depth <br /> 12F-Osw: Wall-Frame, R-21 insulation in 2 x 6 stud 1208 6,909 0 1,672 1,672 I <br /> cavity, no board insulation, siding finish, wood studs ' <br /> 16B-50: Roof/Ceiling-Under Attic with Insulation on Attic 979 1,723 0 1,096 1,096 I <br /> Floor(also use for Knee Walls and Partition <br /> '�, Ceilings), Vented Attic, No Radiant Barrier, Dark <br /> �� Asphalt Shingles or Dark Metal, Tar and Gravel or <br /> Membrane, R-50 insulation <br /> ', 21A-20: Floor-Basement, Concrete slab, any thickness, 2 979 2,326 0 0 0 <br /> or more feet below grade, no insulation below floor, �I <br /> any floor cover, shortest side of floor slab is 20'wide �� <br /> � <br /> Subtotals for structure: 22,952 0 11,304 11,304 � <br /> � People: 2 400 460 860 <br /> '�, Equipment: 0 956 956 ; <br /> , Lighting: 0 0 0 <br /> Ductwork: 0 0 0 0 <br /> Infiltration: Winter CFM: 93, Summer CFM: 50 8,709 716 1,110 1,826 <br /> Ventilation: Winter CFM: 40, Summer CFM: 40 789 578 188 767 <br /> Exhaust: Winter CFM: 50, Summer CFM: 50 <br /> AED Excursion: 0 0 3,512 3,512 <br /> Total Building Load Totals: 32,450 1,694 17,530 19,224 i <br /> ' Check Figures ------ - ------- --- ----------------- -- J �� <br /> Total Building Supply CFM: 812 CFM Per Square ft.: 0.415 �, <br /> Square ft. of Room Area: 1,958 Square ft. Per Ton: 1,222 <br /> Volume (ft3)of Cond. Space: 20,070 <br /> ------------- <br /> ------------ -------------- -- <br /> Building Loads - -- - --- � <br /> Total Heating Required Including Ventilation Air: 32,450 Btuh 32.450 MBH <br /> , Total Sensible Gain: 17,530 Btuh 91 % <br /> Total Latent Gain: 1,694 Btuh 9 % <br /> Total Cooling Required Including Ventilation Air: 19,224 Btuh 1.60 Tons (Based On Sensible + Latent) <br /> - _-- - <br /> -- - _ _ _ -- - <br /> _ ____- <br /> Notes - --------- _------- <br /> - - - - --- � <br /> Rhvac is an ACCA approved Manual J and Manual D computer program. <br /> Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. <br /> , All computed results are estimates as building use and weather may vary. <br /> Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at <br /> � your design conditions. � <br /> � <br /> L - - ----- ----------- --- - -------____J <br /> \\flaresbs\company ...\Nor-Son Construction, Deer Run Remodel.rh9 Thursday, January 12, 2017, 8:28 AM <br />