Laserfiche WebLink
---'--•-----r-�-------- --- - - �� ---------- � - ----------- � - --- . .____.------- -- - ----------- - ------- <br /> � --------------- <br />• Gofden Vall� MNC5542 g37 oommercial HVAC Loads � Elite Software DeeeRu�n RPaoee2l I <br /> - -----_ _ ------ - --- --- <br /> ------ ---------- -- <br /> -- -- - --- - - -i � <br /> - <br /> Pro�ect Report � <br /> - ------ ---- - -------- --- -- <br /> ----- ------- <br /> -----__------ - - --- -- <br /> ' General Project Information 1 <br /> Project Title: Deer Run Remodel <br /> I Designed By: Josh � <br /> Project Date: Thursday, January 12, 2017 I <br /> Client Name: Nor-Son Construction ��I <br /> Company Name: Flare Heating &Air Conditioning <br /> Company Representative: Josh Schindele <br /> Company Address: 9303 Plymouth Ave N � <br /> Company City: Golden Valley, MN 55427 ' <br /> '�, Company Phone: 763-542-1166 I, <br /> Company Fax: 763-542-3101 <br /> Company E-Mail Address: jschindele@flareheating.com � <br /> I Company Website: www.flareheating.com j <br /> � <br /> � IDesign Data------- - --------- ---_ __ ---- — ----- ---- --- � <br /> Reference City: Minneapolis/St. Paul AP, Minnesota <br /> Building Orientation: Front door faces East <br /> Daily Temperature Range: Medium <br /> '�, Latitude: 44 Degrees <br /> I Elevation: 834 ft. <br /> �, Altitude Factor: 0.970 'I <br /> Outdoor Outdoor Outdoor Indoor Indoor Grains '� <br /> Dry Bulb Wet Bulb Rel.Hum Rel.Hum Drv Bulb Difference � <br /> Winter: -16 -16.32 n/a n/a 72 n/a � <br /> �, Summer: 93 71 34% 50% 72 22 <br /> �---- -------------------- ------ — - — -- <br /> ------------------ -- ----- <br /> �, Check Figures_ _ � <br /> Totai Building Supply CFM: 812 CFM Per Square ft.: 0.415 I, <br /> , Square ft. of Room Area: 1,958 Square ft. Per Ton: 1,222 I <br /> Volume (ft3)of Cond. Space: 20,070 I� <br /> � -- --- - ------------ - --- <br /> I I Building Loads � � � -� I <br /> ��, Total Heating Required Including Ventilation Air: 32,450 Btuh 32.450 MBH I <br /> ' Total Sensible Gain: 17,530 Btuh 91 °/o �',I <br /> Total Latent Gain: 1,694 Btuh 9 % I <br /> Total Cooling Required Including Ventilation Air: 19,224 Btuh 1.60 Tons(Based On Sensible + Latent) <br /> I Notes ---- — --- ---- - - - <br /> �', Rhvac is an ACCA approved Manual J and Manual D computer program. ; <br /> ��� Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. <br /> All computed results are estimates as building use and weather may vary. <br /> Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at � <br /> your design conditions. <br /> \\flaresbs\company ...\Nor-Son Construction, Deer Run Remodel.rh9 Thursday, January 12, 2017, 8:28 AM <br />