Laserfiche WebLink
0 <br /> � � <br /> 0 0 <br /> :�;_�y�:.:.�.:. ciTYQ� oRONo <br /> ky <br /> ''� '�'��yA���'�+ - �" Municipal Offices <br /> �' `�,.' �:j rv ;�' `4 <br /> ,\�� ,•.��!�;�-�����;����: G�� Street Address• q5a-a4q-�6o O g <br /> Mailin Address: <br /> ��- '� '�'.i�,:� �i/ <br /> '��.�9 '4�,;� 2150 Kelley Parkway P.O. Box 66 <br /> \Esx��" Orono, MN 55356 Crystal Bay, MN 55323•0066 <br /> To Current Owner: Address: ��� !-�� '� �"�°� <br /> City Ordinance 199 requires that each existing on-site sewage treatment system in Orono be inspected every two years. <br /> The on-site sewage treatment system at the above address has been inspected and appears to fall into the categories checked below. <br /> SYSTBM CONFORMITY (1-3): � <br /> 1 "CODE SYST'EM" An ISTS which meets all the location,design and constuction standards of the current Orono Municipal Code. <br /> 2 "COMPLIANT SYSTEM" An ISTS whicli does not meet all the tocation,design and construction standards of the current Orono <br /> Municipal Code but does meet the tbree foot sepazation requirement or rivo foot requirement for systems installed 1996 or eaziier,and <br /> which is not failing or an imiminent threat to public health or safety. <br /> 3 "NON-COMPLIANT SYSTEM" A prohibited ISTS;an ISTS]ocated within a designated 100-year flood plain,any ISTS which may <br /> or may not meet all tUe location,design,or cons�uction stan3ards of the current Orono Municipal Code and which is failing for any <br /> reason;and any ISTS with less than three feet of unsaturated soil or sand between the distribution device and the limiting soil characteristics. <br /> TANK CONDITION(5-71: .� <br /> Tank inspection indicates: <br /> 5 Pumpout not needed at this time. <br /> 6 Septic tanks must be pumped out this year (city code recommends tanks to be pumped out once every 3 years. <br /> Tank was last pumped )• <br /> Make sure seatic tanks are pumaed throu�h manhole and not throush white insoection piaes. This allows for the proper <br /> cleanins Keep water softner and iron filter discfiarse out of septic svstem to prolons life of drainfield. Ask pumper to test <br /> alarm float to verifv alarm is still workins in vour house The alarm warns owner that septa¢e is about to backup into basement._ <br /> 7 Inspection risers missing-tanks could not be inspected. Inspection risers(4" dia.pipe)must be mstalled m each tanic. If <br /> tanks have not been pumped out within the last three years,they should be pumped out now. <br /> DRAINFIELD CONDITION(8-10): � <br /> 8 Drainfield is dry,no surfacing evident. <br /> 9 Some evidence of surfacing,not critical yet. <br /> 10 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector <br /> immediately.Repairs must be completed within 90 days. <br /> COMMENTS: <br /> c, _ d2 -v , l,� ��` <br /> Date of Inspection Septic System Inspector <br />