. � <br />• � � ' • <br /> Provide Exterior or Exposure 1 grade. Panels shall be continuous over two or more spans, and long <br /> dimension of panel shall be perpendicular to supports. Fasten roof sheathing with 8d nails (.131" <br /> diameter x 2 1/2") spaced at 4"o.c. at supported edges and 8"o.c. at intermediate supports. Leave an <br /> 1/8"gap at all end and edge joints to allow for expansion. Design of roof sheathing assumes that the roof <br /> will be properly insulated and ventilated. Refer to APA publication N335N "Proper Installation of APA <br /> Rated Sheathing for Roof Applications." <br /> FLOOR SHEATHING <br /> Floor sheathing shall be minimum 23/32"thick tongue and groove APA rated panels, rated for spacing of <br /> supporting members. A minimum of 48/24 span rating is recommended. Provide Exposure 1 grade. <br /> Panels shall be continuous over two or more spans, and long dimension of panel shall be perpendicular <br /> to supports. Fasten sheathing with construction adhesive and 10d nails(.148"diameter x 3")spaced at <br /> 4"o.c. at supported edges and 8"o.c. at intermediate supports. <br /> LVL WOOD MEMBERS <br /> LVL members noted on drawings are engineered laminated veneer lumber as manufactured by the iLevel <br /> -Weyerhaeuser Company. Alternate at contractor's option of equal design properties. <br /> Sizes shown on plan are actual size. <br /> CHIMNEY FRAMING <br /> At chimney's higher than 3' measured from top of wood framing to top of highest contacting roof deck <br /> elevation,the following general guidelines apply: <br /> Frame with continuous 2 x 4 material from the top of the chimney to attic floor. <br /> For discontinuous walls, provide triple plates bolted together at corners and Ca� 32"oc with sheathing <br /> butted at center plate. <br /> Provide (2) plates at top of chimney, lap these plates at corners. <br /> Brace laterally at roof top and bottom chords with blocking and strapping to adjacent trusses at each side <br /> of chimney for support in all directions. <br /> Sheath all sides full height with 5/8"plywood blocked at joints ar�d nailed with 6:12 nailing pattern. <br /> Notes represent a guideline only, on-site determination of exact blocking and framing systems to be <br /> determined by the contractor. <br /> PRECAST CONCRETE UNITS <br /> The design of all precast concrete units shall conform to ACI 318. <br /> Submit complete shop drawings to architect for approval,showing the erection plan, all bearing <br /> conditions, and anchorage details. <br /> Prestressed units to sustain the loads indicated in addition to alt other dead loads. <br /> Plank supplier shall design plank to support additional dead load from, but not limited to <br /> piping, ductwork, etc.. Coordinate with mechanical/electrical as required. <br /> Precast concrete walls shall be anchored to the foundation and to each other. <br /> The precast designer shall design the connections for fastening precast units to foundations, to each <br /> other, and to other supporting members. <br /> Floor plank shall be prestressed hollow-core slabs,proportioned for the loads noted on the drawings. <br /> Upon installation, plank shall be essentially past the effects of deformation due to creep and shall have <br /> camber not over 1/360 of the span. Such camber shall be uniform from plank to plank. <br /> All headers at openings in precast concrete shall be furnished by precast suppliers. <br /> Place mechanical openings not shown on plans between webs in precast concrete plank units. <br /> Do not drill holes into precast concrete plank without prior approval from plank supplier. <br /> Wet the surface of the precast plank to surface saturated dry condition and broom in portland cement <br /> slurry immediately prior to casting topping slab. A properly applied bonding agent is acceptable in lieu of <br /> the wet slurry provided it is installed in strict accordance to manufacturer's instruction. <br /> Appendix A,Highwood Road Residence,23Jan2013,MMY#: 13042.00,APG <br /> Page 6 <br />