My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2013-00005 - new structure
Orono
>
Property Files
>
Street Address
>
H
>
Highwood Road
>
4156 Highwood Road - 07-117-23-44-0019
>
Permits/Inspections
>
2013-00005 - new structure
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 5:40:14 PM
Creation date
2/15/2017 3:10:06 PM
Metadata
Fields
Template:
x Address Old
House Number
4156
Street Name
Highwood
Street Type
Road
Address
4156 Highwood Rd
Document Type
Permits/Inspections
PIN
0711723440019
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
43
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
, . , � , <br /> conform to Voluntary Product Standard PS 2-92, as published by the Department of Commerce. <br /> WOOD TRUSSES <br /> Responsibilities ot the contractor, building designer, truss manufacturer, and truss designer shall follow <br /> the publication 'TPI 1-2002 National Design Standard for Metal Plate Connected Wood Truss <br /> Construction." <br /> Truss supplier shall notify SER of any proposed revisions to the layout indicated on this plan. Revisions <br /> that affect the structural design will not be allowed without prior written approval by the SER. <br /> Verify a�lowable bearing locations for girder trusses with SER prior to final design stage. Provide metal <br /> bearing enhancers as necessary to uti�ize stud columns shown on plan. <br /> Trusses shall be designed for top and bottom chord superimposed dead and live loads as indicated <br /> above. <br /> Truss supplier shall design trusses to support additional dead load from,but not limited to piping, <br /> ductwork, etc. Coordinate with mechanical/electrical as required. General contractor to verify location <br /> and magnitude of all such loads with truss supplier prior to fabrication of trusses. <br /> Coordinate any draft stop locations and design trusses accordingly. <br /> Live load deflection of roof trusses shall be limited to 1/240 of the span. <br /> Live load deflection of floor trusses shall be limited to 1/480 of the span. <br /> Design trusses for bearing as shown on drawings. <br /> Truss configuration,pitch,overhang, etc.shall be indicated on the architectural drawings. <br /> Spacing of roof trusses shall not exceed 24"o.c. <br /> Spacing of floor trusses shall not exceed 19.2"o.c. <br /> Lumber for wood trusses shall be in accordance with manufacturer's recommendations. <br /> Truss manufacturer to provide girder trusses, hip jacks, and step-down trusses as required and designed <br /> to support all superimposed loads. Provide hip-sets, dormers, and piggy-back trusses as required. <br /> Truss manufacturer to specify if roof sheathing needs to be applied before placing "over-framing". <br /> Provide metat framing anchors at truss bearing to mechanically fasten truss to bearing wall or supporting <br /> member as shown in details. <br /> Truss manufacturer shall provide truss to truss connection hangers. <br /> Bridging, and bracing of truss compression and tension members, shall be installed in accordance with <br /> the truss manufacturer's design and directions. <br /> No cutting, notching, or modifications of trusses will be allowed without the manufacturer's written <br /> approval. <br /> Contractor shall provide permanent and temporary diagonal, lateral, and cross bracing in accordance with <br /> the publication "BCSI 1-03 Building Component Safety Information, Guide to Good Practice for Handling, <br /> Installing and Bracing of Metal Plate Connected Wood Trusses" by the Truss Plate Institute and Wood <br /> Truss Council of America and as otherwise necessary. <br /> Permanent bottom chord bracing and web bracing shall be located as shown on the truss drawings and <br /> shall be minimum 2 x 4 with 2- 16d nails to end walls and trusses, lapping two truss spaces at splices. <br /> WALL SHEATHING <br /> Wall sheathing shall be minimum 15/32"thick APA rated panels, rated for spacing of supporting <br /> members. A minimum 32/16 span rating is recommended. <br /> Provide Exterior or Exposure 1 grade. Panels shall be continuous over two or more spans, and long <br /> dimension of panel shall be either perpendicular or parallel to supports. Fasten wall sheathing with 8d <br /> nails (.131"diameter x 2 1/2") spaced at 4" o.c. at supported edges and 8" o.c. at intermediate supports. <br /> Leave an 1/8"gap at all end and edge joints to allow for expansion. Stagger end joints of panels. Refer <br /> to plan and notes for any special shear walt nailing and bolting conditions. Gypsum sheathing to be a <br /> minimum of 1/2"thick fastened with 6d cooler or wallboard nails at 7" o.c. to all framing members unless <br /> noted otherwise. <br /> ROOF SHEATHING <br /> Roof sheathing shall be minimum 19/32"thick APA rated panels, rated for spacing of supporting <br /> members. A minimum of 40/20 span rating is recommended. Provide panel clips, one between each <br /> support, for supports spaced greater than 16"o.c. <br /> Appendix A,Highwood Road Residence,23Jan2013,MMY#: 13042.00,APG <br /> Page 5 <br />
The URL can be used to link to this page
Your browser does not support the video tag.