Vapor R�tarder: <br /> - i� Installed on the warm-in-winter side of all non-vented framed ceilings,walls,and floors. <br /> Materials Identification: <br /> � Materials and equipment are installed in accordance with the manufacturer's installation instructions. <br /> � Materials and equipment are identified so that compliance can be determined. <br /> � Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment have been provided. <br /> � Insulation R-values,glazing U-factors,and heating equipment efficiency are clearly marked on the building pians or specifications. <br /> � Insulation is installed according to manufacturer's instructions,in substantial contact with the surface being insulated,and in a manner <br /> that achieves the rated R-value without compressing the insulation. <br /> Duct Insulation: <br /> � Supply ducts in unconditioned attics or outside the building are insulated to at least R-11. <br /> � Return ducts in unconditioned attics or outside the building are insulated to at least R-6. <br /> � Supply ducts in unconditioned spaces are insulated to at least R-11. <br /> � Return ducts in unconditioned spaces(except basements)are insulated to R-2.Insulation is not required on return ducts in basements. <br /> � Where exterior walls are used as plenums,the wall is insulated to at least R-11. <br /> Duct Construction: <br /> � Duct connections to flanges of air distribution system equipment are sealed and mechanically fastened. <br /> U All joints,seams,and connections are securely fastened with welds,gaskets,mastics(adhesives),mastic-plus-embedded-fabric,or <br /> tapes.Tapes and mastics are rated UL 181A or UL 1816. <br /> Exceptions: <br /> Continuously welded and locking-type longitudinal joints and seams on ducts operating at less than 2 in.w.g.(500 Pa). <br /> � The HVAC system provides a means for balancing air and water systems. <br /> Temperature Controls: <br /> � Thermostats exist for each separate HVAC system.A manual or automatic means to partially restrict or shut off the heating and/or <br /> cooling input to each zone or floor is provided. <br /> Service Water Heating: <br /> U Water heaters with vertical pipe risers have a heat trap on both the inlet and outlet unless the water heater has an integral heat trap or <br /> is part of a circulating system. <br /> � Circulating hot water pipes are insulated to the levels in Table 1. <br /> Circulating Hot Water Systems: <br /> � Circulating hot water pipes are insulated to the levels in Table 1. <br /> Swimming Pools: <br /> � All heated swimming pools have an on/off heater switch and a cover unless over 20%of the heating energy is from non-depletable <br /> sources.Pool pumps have a time clock. <br /> Heating and Cooling Piping Insulation: <br /> � HVAC piping conveying fluids above 105 degrees F or chilled fluids below 55 degrees F are insulated to the levels in Table 2. <br /> Project Title:AI and Renee Seam 2 ti� � � �hM � ���� � �� � ����� ���� Report date: 08/12/09 <br /> Data filename: Page 3 of 4 <br />