Laserfiche WebLink
13-3637 <br /> 1Vovember 14,2013 <br /> Page 6 <br /> Additionally, the development is subject to the Stormwater and Drainage Trunk Fee, which <br /> should be based on an equivalence to the standard fee for the 1/2-acre zoning district given the <br /> lot sizes proposed. That fee is $5,765 per gross acre, and at 4.92 gross acres (net of Willow <br /> Drive r-o-w) amounts to $28,364.00. <br /> Lot Layout and Lot Standards <br /> The property is situated generally along the east side of Willow Drive just north of Watertown <br /> Road. Access to the property will be off of Willow Drive via a short public road with cul-de-sac. <br /> Minimum pertinent lot standards for the RPUD District are as follows: <br /> Minimum lot area: 15,000 s.f. <br /> Minimum lot width: 90' <br /> Minimum lot depth: 125' <br /> Setbacks: Front: 25' <br /> Side local street: 25' <br /> Side collector street: 50' <br /> Side interior to RPUD: 10' <br /> Side abutting non-RPUD land: 15' <br /> Rear: Lesser of 40' or 20% of lot depth <br /> Wetland boundary: 35' <br /> Note that 78-626(16)allows for flexibility in RPUD standards: <br /> (16) Flexibility. The uniqueness of each RPUD requires that specific�tions and standards for <br /> streets, utilit�es,public.facilities and subdivisions may be subject to modification from the <br /> city ordinances ordinarily governing them. The city council may tJzerefore approve <br /> streets, utilities,public facilities and[and subdivisions which are not in compli�nce with <br /> usual specifications or ordinance requirements, if it finds that strict adherence to suclz <br /> standards or requirements is not required to meet the intent of this section or to protect <br /> t/ae/zealth, safety or welfare of the residents of the RPtID, the surrounding area or the <br /> city as a whole. <br /> A review of characteristics of each proposed lot appears below. Issues or inconsistencies with <br /> RPUD code standards are highlighted in bold type: <br /> Lot 1, Block 1 Proposed Lot 1, Block 1 will have 0.32 acres of dry buildable land (13,997 <br /> s.f.) for the building site (slightly under the RPUD standard) with 0.56 <br /> acres of wetland behind it. This lot will be a corner lot, with the front lot line <br /> being the frontage along the new road. Proposed lot width is 91' meeting the <br /> RPUD standard. Proposed buildable envelope is shown meeting RPUD <br /> setbacks from front, interior side and wetland; however, as Willow Drive is <br /> defined as a collector road in the CMP, the side street setback to Willow <br /> should be 50' but is shown at 25'. <br />