Laserfiche WebLink
�_ \ <br /> �. � . <br /> � � \�,1 <br /> '� - �`1 +� C IT� of UROl\TO <br /> �, <br /> ,..y\`..• ':Y': <br /> ��, � �i', r.��,y ... Y7 <br /> �`,, 4' l,� '��I , �ti Municipal Offices <br /> � 1 '``�` G Street Address: �15a-a49-�16o O <br /> .L .� Mailing Address: <br /> 9$EgKO�' 2750 Kelley Parkway P.O. Box 66 <br /> Orono, MN 55356 Crystal Bay, MN 55323-0066 <br /> To Current Owner: Address: � I Q� �C��^ �r�t S �V <br /> City Ordinance 199 requires that each existing on-site sewage treatment system in Orono be inspected every two years. <br /> The on-site sewage treatment system at the above address has been inspected and appears to fall into the categories checked below. <br /> SYSTEM COIv'FORMITY 1-3 : � <br /> 1 - "GODE SYST'EM" An ISTS which meets all the location,design and construction standards of the current Orono Municipal Code. <br /> 2 "COMPLIANT SYSTEM" An ISTS which does not meet ail the location,design and construction standards of the current Orono <br /> Municipal Code but does meet the three foot separation requirement or rivo foot requirement for systems installed 1996 or earlier,and <br /> which is not failing or an iuuninent threat to public health or safety. <br /> 3 "NON-COMPLIANT SYSTEM" A prohibited ISTS;an ISTS located within a designated 100-year flood plain,any ISTS which may <br /> or may not meet all the location,design,or construction stan�ards ofthe current Orono Municipal Code and which is failing for any <br /> reason;and any ISTS with less than three feet of unsaturated soil or sand between the distribution device and the luniting soil characteristics. <br /> TANK CONDITION(5-7): � <br /> Tank inspection indicates: <br /> QPumpout not needed at this time. <br /> 6 Septic tanks must be pumped out this year (city code recommends tanks to be pumped out once every 3 years. <br /> Tank was last pumped �—�—0`� ). <br /> Make sure septic tanks are pumped through manhole and not throueh white inspection pipes. This allows for the proper <br /> cieaning. Keep water softner and iron filter dischar�e out of septic svstem to prolong life of drainfield. Ask pumper to test <br /> alarm float to verifv alarm is still working in vour house. The alarm warns owner that septage is about to backup into basement. <br /> 7 Inspection risers missing-tanks could not be inspected. Inspection risers(4"dia.pipe)must be installed in each tank. If <br /> tanks have not been pumped out within the last three years,they should be pumped out now. <br /> DRAINFIELD CONDITION(8-10): 2f <br /> 8� Drainfield is dry,no surfacing evident. <br /> 9 Some evidence of surfacing,not critical yet. <br /> 10 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector <br /> immediately.Repairs must be completed within 90 days. <br /> COMMENTS: ���,��.�c�� __ �-- Scp }�.L ��.I�S �OaK OK. <br /> �-�-a u �1�� �,��. <br /> Date of Inspection Matt Bolterman - Septic System Inspector <br /> Note: ln the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property. be advised that tliis report does <br /> noi �uarintee or certif}� that an e�isting system will continue to fiu�ction properl�. but is merely an opinion of the adequacy of thz s}stem undi:r current <br /> �undilions bascd on the a��ailablc inlomiation. <br />