My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2011-00075 new house
Orono
>
Property Files
>
Street Address
>
G
>
Graham Hill Road
>
3215 Graham Hill Road - 05-117-23-14-0066
>
Permits/Inspections
>
2011-00075 new house
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 5:18:54 PM
Creation date
1/9/2017 1:35:32 PM
Metadata
Fields
Template:
x Address Old
House Number
3215
Street Name
Graham Hill
Street Type
Road
Address
3215 Graham Hill Rd
Document Type
Permits/Inspections
PIN
0511723140066
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
69
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
� GENERAL NOTES: <br /> 1. DO NOT BACKFILL BASEMENT WALLS UNTIL THE CONCRETE HAS REACHED A MINIMUM COMPRESSIVE STRENGTH OF 2250 PSI. IN ADDITION,DO <br /> NOT BACKFILL UNTIL THE BASEMENT WALLS ARE SUPPORTED BY THE FINAL INSTALLED FLOOR CONSTRUCTION AT BOTH THE TOP AND BOTTOM, <br /> UNLESS ADEQUATE SHORING IS INSTALLED AS REQUIRED. SHORING IS THE RESPONSIBILITY OF THE GENERAL CONTRACTOR,UNLESS NOTED <br /> OTHERWISE. <br /> 2. STRIP FOOTINGS MAY BE PLACED AT ELEVATIONS LOWER THAN SHOWN IN THE DETAILS. <br /> 3. 1y"DEEP BY�"WIDE BY CONTINUOUS KEYWAYS,LOCATED ANYWHERE WITHIN THE WALL WIDTH,MAY BE USED IN LIEU OF DOWELS FOR FULL <br /> HEIGHT AND FROST WALLS. <br /> 4. STRIP FOOTING TO WALL CENTERLINES MAY BE OFFSET UP TO 2". A MINIMUM OF 2"OF STRIP FOOTING IS TO EXTEND BEYOND THE WALL FACE <br /> EACH SIDE. <br /> 5. PROVIDE CODE REQUIRED FROST PROTECTION TO THE BOTTOM OF ALL FOOTINGS. <br /> 6. SLOPE GRADE DOWNWARD AWAY FROM THE STRUCTURE A MINIMUM OF 6"WITHIN THE FIRST TEN FEET UNLESS ADEQUATE DRAINS OR SWALES <br /> ARE PROVIDED. <br /> 7. BOTH MATERIALS AND INSTALLATION OF DRAIN TILE,WATER-PROOFING,CONTROL JOINTS,FLASHING,AND INSULATION ARE TO BE IN <br /> ACCORDANCE WITH THE CODE BY THE GENERAL CONTRACTOR,UNLESS NOTED OTHERWISE. <br /> 8. ALL WALL WIDTHS SHOWN ARE NOMINAL DIMENSIONS,UNLESS NOTED OTHERWISE.OVERALL WALL THICKNESS MAY VARY BY UP T01/2"FROM <br /> THAT SHOWN. <br /> 9. REINFORCING PLACEMENT TOLERANCE IS 1/2". BARS BEING SPLICED ARE TO BE WITHIN 2"OF CENTERLINE. MINIMUM SPLICE LENGTNS ARE 30 <br /> BAR DIAMETERS FOR GRADE 40 STEEL AND 48 BAR DIAMETERS FOR GRADE 60 STEEL. TYING IS NOT REQUIRED PROVIDED THESE TOLERANCES <br /> ARE MET. <br /> 10. PROVIDE MATCHING HOOK BARS FOR ALL HORIZONTAL BARS AT WALL CORNERS AND INTERSECTIONS. HORIZONTAL BARS MAY BE PLACED <br /> ANYWHERE WITHIN THE WALL WIDTH AS LONG AS A MINIMUM OF 2"OF CLEAR COVER IS PROVIDED. <br /> 11. REINFORCING MAY BE BUNDLED UP TO A MAXIMUM OF THREE BARS. <br /> 12. DOWELS MAY BE DRILLED AND GROUTED IN PLACE. VERTICAL BARS AND DOWELS DO NOT NEED TO ALIGN. VERTICAL BARS MAY BE DRILLED <br /> AND EMBEDDED 5"INTO THE STRIP FOOTING IN LIEU OF DOWELS. <br /> 13. THE BOND BETWEEN CONCRETE AND REINFORCING WILL NOT BE APPRECIABLY REDUCED IF FORM OIL IS PRESENT FOR THE CONDITIONS <br /> CONTAINED WITHIN THESE DRAWINGS. <br /> 14. SILL PLATES ARE TO BE ANCHORED WITH A MINIMUM OF TWO ANCHORS PER SILL SECTION. ALL SECTIONS ARE TO HAVE AN ANCHOR WITHIN 4" <br /> T012"OF EACH END. AN ANCHOR IS TO BE PLACED AT ALL WALL CORNERS AND INTERSECTIONS ON WALLS MORE THAN TWO FEET IN LENGTH. <br /> WALLS TWO FEET OR LESS IN LENGTH REQUIRE A MINIMUM OF ONE ANCHOR. REQUIREMENTS FOR SHEAR WALLS AND BRACED PANELS MAY BE <br /> IN EXCESS OF THESE REQUIREMENTS.TWO INCH WASHERS ARE ONLY REQUIRED AT FULL HEIGHT FOUNDATION WALLS. <br /> 15. SILL PLATES ARE NOT REQUIRED TO BE TREATED IN ACCORDANCE WITH IRC SECTION R319.1 ITEM 2 PROVIDED GRADE IS 8"FROM WOOD <br /> MATERIALS. ANCHOR BOLTS 1/2"OR LARGER IN DIAMETER ARE NOT REQUIRED TO BE CORROSION PROTECTED IN ACCORDANCE WITH IRC <br /> SECTION R319.3 EXCEPTION 1. CENTER BOLTS ON PLATE. <br /> 16. ALL PRE-MANUFACTURED FASTENERS AND CONNECTORS ARE TO BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S REQUIREMENTS. <br /> 17. FLOOR BLOCKING IS ONLY REQUIRED AT FULL HEIGHT FIRST FLOOR NON-BEARING FOUNDATION WALLS. <br /> 18. CARE IS TO BE TAKEN DURING CONCRETE PLACEMENT TO MINIMIZE INADEQUATE HORIZONTAL AND DIAGONAL COLD JOINTS,AND TO PREVENT <br /> THESE JOINTS ENTIRELY IN WALLS WITHOUT VERTICAL REINFORCEMENT. ADEQUATELY VIBRATE CONCRETE AT POTENTIAL JOINT LOCATIONS, <br /> AS REQUIRED BASED ON PLACEMENT CONDITIONS,TO ELIMINATE HONEYCOMBING AND TO ENSURE SUFFICIENT BONDING. <br /> Rev �ate 2011 MASTER C.I.P. CONCRETE SITE ADDRESS: <br /> FOUNDATION DRAWINGS <br /> GENERALNOTES <br /> CLIENT INFORMATION: � <br /> CHARLES CUDD DE NOVO City: State: zip: <br /> 15050 23RD AVENUE NORTH 5201 EastSuter308 <br /> PLYMOUTH, MN 55447 Project Number: 10.02628 ^^ ""'��Te 7635N152500 <br /> Drawing Date: 01-01-11 { FaY763-577-1168 <br /> Phone: 612-333-8020 Fax: 612-335-5071 Sheet: 3of 16 Jv �uww.ulteig.com <br /> OO COPYRIGHT ULTEIG ENGINEERS INC.2011 <br />
The URL can be used to link to this page
Your browser does not support the video tag.