Laserfiche WebLink
' DRAWING USE GUIDELINES AND LIMITATIONS: <br /> THE CONTRACTOR IN THE TITLE BLOCK BELOW IS LICENSED BY ULTEIG TO USE THIS PACKET WITHIN THE LIMITATIONS NOTED FOR PROJECTS IN <br /> WHICH THE LICENSEE IS DIRECTLY RESPONSIBLE. THE LICENSEE MAY RELEASE THIS PACKET TO ITS SUB-CONTRACTORS AND CLIENTS FOR USE IN <br /> THE PROCUREMENT OF BUILDING PERMITS.A COPY OF THIS PACKET AND A LIST OF THE CURRENT AUTHORIZED CONTRACTORS IS AVAILABLE AT <br /> WWW.ULTEIG.COM. <br /> THE PACKET IS TO BE ISSUED TO THE APPROPRIATE BUILDING DEPARTMENT IN ACCORDANCE WITH THEIR APPROVED PROCEDURE FOR USE BY THE <br /> BUILDING AGENCY DURING PLAN REVIEW AND INSPECTION. <br /> THE FOLLOWING LIMITATIONS APPLY TO THESE DRAWINGS: <br /> 1. BASEMENT FOUNDATION WALLS TEN FOOT OR LESS IN CLEAR HEIGHT(CLEAR HEIGHT IS FROM TOP OF SLAB TO TOP OF CONCRETE WALL AT <br /> SILL PLATE BEARING-NOT NECESSARILY BASEMENT CEILING HEIGHT) <br /> 2. OVERALL BUILDING HEIGHT NOT EXCEEDING TWO STORIES PLUS THE BASEMENT <br /> 3. OVERALL BUILDING BASEMENT WIDTH NOT EXCEEDING 60 FEET <br /> 4. STRUCTURES OF WOOD FLOOR,ROOF,AND WALL CONSTRUCTION ONLY <br /> 5. EXTERIOR GRADE SLOPING DOWNWARD AWAY FROM THE FOUNDATION WALLS <br /> SPECIAL CONSIDERATION AND SITE SPECIFIC DESIGN IS REQUIRED FOR CONDITIONS BEYOND THESE LIMITS. <br /> COLD WEATHER GUIDELINES: <br /> 1. THE CONTRACTOR AND CONCRETE SUPPLIER ARE TO WORK TO OBTAIN A MIX WHICH WILL ADEQUATELY PERFORM UNDER THE EXPECTED <br /> CONSTRUCTION CONDITIONS. THE USE OF ADDITIONAL CEMENT,HIGH-EARLY STRENGTH CONCRETE,ANDIOR ACCELERATOR IS <br /> RECOMMENDED AT TEMPERATURES LESS THAN TWENTY DEGREES F. <br /> 2. DELIVER CONCRETE WARM AND IN A TIMELY MANNER. PLACE CONCRETE EARLY IN THE DAY WHEN POSSIBLE. <br /> 3. DO NOT ADD ADDITIONAL WATER TO THE CONCRETE. THE USE OF WATER-REDUCING AGENTS IS RECOMMENDED WHEN WORKABILITY IS OF <br /> CONCERN. NO CONCRETE IS TO BE PLACED ON SNOW OR IN CONTACT WITH FROZEN MATERIALS. <br /> 4. REBAR DOES NOT NEED TO BE PRE-HEATED,BUT IS TO BE FREE OF FROST,SNOW,AND ICE. <br /> 5. BLANKETS OR OTHER ACCEPTED PROTECTION IS HIGHLY RECOMMENDED FOR THE TOP 24"OF WALLS WHEN THE AIR TEMPERATURE IS LESS <br /> THAN TEN DEGREES F AND FOR THE FULL HEIGHT OF THE WALL WHEN THE AIR TEMPERATURE IS LESS THAN ZERO DEGREES F. <br /> THESE COLD WEATHER GUIDELINES ARE GENERAL RECOMMENDATIONS ONLY. RESPONSIBILITY OF ACHIEVING ADEQUATE FINAL IN-PLACE <br /> CONDITION IS BY THE CONTRACTOR. <br /> MATERIALS: <br /> CONCRETE: MIX TO BE DESIGNED AND PROPORTIONED BY THE CONCRETE SUPPLIER <br /> F'c=3,000 PSI MIN AT 28 DAYS <br /> STEEL: #4 BARS-Fy=40 KSI(ASTM A615) <br /> #5 BARS&GREATER-Fy=60 KSI(ASTM A615) <br /> SOIL BEARING: 1500 PSF MIN <br /> EQUIVALENT REBAR TABLE <br /> FOR BUNDLED HORIZONTAL BARS <br /> (2)#4=(1)#6 <br /> (3)#4=(2)#5 <br /> (3)#5=(2)#6 <br /> Rev Date 2011 MASTER C.I.P. CONCRETE SITE ADDRESS: <br /> FOUNDATION DRAWINGS <br /> DRAWING LIMITATIONS AND MATERIALS <br /> CLIENT INFORMATION: • _� <br /> CHARLES CUDD DE NOVO City: State: Zip: <br /> 5201 East River Rd <br /> 15050 23RD AVENUE NORTH Suite308 <br /> PLYMOUTH, MN 55447 ProjectNumber: 10.02628 ^� "^'�"TP�63sN,5�o0 <br /> Drawing Date: 01-01-11 � Fax763-571-1168 <br /> Phone: 612-333-8020 Fax: 612-335-5071 Sheet: 2of 16 V �.���e�9.�om <br /> OO COPYRIGHT ULTEIG ENGINEERS INC.2011 <br />