. • ` •'. <br /> Figure 6 Exposed Foundation Wall Area: Concrete Block or Poured <br /> Concrete Foundation Area: 175.0 square feet <br /> Interior Air Film 0.61 � <br /> Continuous Vapor Barrier 0.00 __ <br /> Foundation Wall 1.89 <br /> Insulation 10.00 <br /> Exterior Air Film 0.17 �� <br /> Total Assembly R-Value 12.67 ' � / �'� �' <br /> �, <br /> Assembly U-Value (1/R) 0.08 'i <br /> (entered on Page 1) �� � <br /> ����� <br /> � <br /> I I <br /> �i <br /> t'i < ° - <br /> � <br /> � <br /> Notes: <br /> 1.) Only the above grade area of the foundation wall is to be included in the <br /> energy calculations <br /> 2.) The Engery Code requires that, if the floor above the basement or crawl space <br /> is not insulated, the foundation wall must be insulated. Either the foundation <br /> must have a minimum R-10 insualtion applied from the top of the foundation <br /> to the frost line or a minimum R-5 insualtion applied over the entire foundation <br /> wall. The R-Value specified is for the insulation material only. <br /> 3.) If rigid foam insualtion is to be applied to the exterior of the foundation wall, the above <br /> grade portion must be protected from the sun, the weather and physical abuse. <br /> 4.) If ridgid foam insulation is to be applied to the interior, it must be protected by minimum <br /> 1/2"gypsum board or equal (as specified in section 1712 of the Uniform Building Code). <br />