My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2016-01257 - building permit application/COO
Orono
>
Property Files
>
Street Address
>
C
>
Casco Point Road
>
2649 Casco Point Road - 20-117-23-24-0029
>
Permits/Inspections
>
2016-01257 - building permit application/COO
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 3:54:45 PM
Creation date
11/22/2016 11:53:31 AM
Metadata
Fields
Template:
x Address Old
House Number
2649
Street Name
Casco Point
Street Type
Road
Address
2649 Casco Point Road
Document Type
Permits/Inspections
PIN
2011723240029
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
89
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
. 1�. . . <br /> - --- _ _- - -- - _. -- - -- , <br /> � Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc. I <br /> �West Metro Mechanical Inc. � Kindl Residence I <br /> ' Norwood MN 55368 _ _ ___ __ ___ Page 15 i <br /> - - -- - - - - - - - - - - -- - - - - - _ _ _ --_- _ � <br /> j i Detailed Room Loads - Room 8 - 2nd Story Bed 2, Bath, Laundry, Hall, Bed 3, <br /> � Closet Avera e Load Procedure� __ <br /> General <br /> Calculation Mode: Htg. &clg. Occurrences: 1 <br /> I Room Length: 42.5 ft. System Number: 1 <br /> II Room Width: 40.0 ft. Zone Number: 1 � <br /> Area: 1,700.0 sq.ft. Supply Air: 269 CFM � <br /> � Ceiling Height: 8.0 ft. Supply Air Changes: 1.2 AC/hr <br /> � Volume: 13,600.0 cu.ft. Req. Vent. Clg: 0 CFM ' <br /> ! Number of Registers: 3 Actual Winter Vent.: 46 CFM ' <br /> i Runout Air: 90 CFM Percent of Supply.: 17 % ! <br /> � Runout Duct Size: 6 in. Actual Summer Vent.: 45 CFM I <br /> I Runout Air Velocity: 457 ft./min. Percent of Supply: 17 % I <br /> � Runout Air Velocity: 457 ft./min. Actual Winter Infil.: 41 CFM <br /> i Actual Loss: 0.131 in.wg./100 ft. Actual Summer Infil.: 22 CFM <br /> _ _ _- -.- -._-_ <br /> I item Area -U- Htg Sen Clg Lat Sen <br /> I II Description Quantity Value HTM Loss HTM Gain Gain ! <br /> I W-Wall-12F-Osw 24 X 8 149.6 0.065 5.3 788 1.1 0 159 I <br /> j S-Wall-12F-Osw 42.5 X 8 331.7 0.065 5.3 1,746 1.1 0 351 � <br /> i N -Wall-12F-Osw 42.5 X 8 306.7 0.065 5.3 1,615 1.1 0 325 I <br /> i E-Wall-12F-Osw 18 X 8 128 0.065 5.3 674 1.1 0 136 j <br /> i W-Gls-1 F-hw-o shgc-0.3 0%S (2) 11.1 0.440 35.6 396 35.1 0 390 j <br /> W-Gls-1 F-hw-o shgc-0.3 0%S 10.4 0.440 35.6 371 35.0 0 365 i <br /> �I W-Gls-1 F-hw-o shgc-0.3 0%S (2) 20.8 0.440 35.6 742 35.0 0 730 I <br /> S-Gis-1 F-hw-o shgc-0.3 0%S 5.6 0.440 35.6 198 20.7 0 115 <br /> I S-Gls-1 F-hw-o shgc-0.3 0%S 2.8 0.440 35.6 99 20.9 0 58 <br /> I N -Gls-1 F-hw-o shgc-0.3 100%S 6.9 0.440 35.6 247 12.7 0 88 I <br /> I N -Gls-1 F-hw-o shgc-0.3 100%S (2) 5.6 0.440 35.6 198 12.6 0 70 � <br /> I N -Gls-1 F-hw-o shgc-0.3 100%S (2) 20.8 0.440 35.6 742 12.8 0 266 I <br /> I E-Gls-1 F-hw-o shgc-0.3 0%S (2) 5.6 0.440 35.6 198 34.9 0 194 I <br /> I E-Gls-1 F-hw-o shgc-0.3 0%S 10.4 0.440 35.6 371 35.0 0 365 � <br /> I UP-Cei1-16B-50 42.5 X 40 _ _ _ _ 1700_ _ _0.020 _ _ _1.6_ _ 2,754 _ _ __ 1.0 _ _ _ _ 0_ _1 734 � <br /> I Subtotals for Structure: 11,139 0 5,346 � <br /> Infil.: Win.: 40.9, Sum.: 21.9 1,016 3.481 3,537 0.368 434 374 � <br /> � AED Excursion:_ _ . _ _ _ _ _ _ _ _ _ _ 23 <br /> � Room Totals: 14,676 434 5,743 <br /> -- - - - - - - - -- _- -� <br /> C:\...\Kindl Residence.rh9 Thursday, September 29, 2016, 12:18 PM <br />
The URL can be used to link to this page
Your browser does not support the video tag.