� 1� , <br /> Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc. <br /> West Metro Mechanical Inc. � Kindl Residence, , <br /> Norwood MN 55368 Page 14 <br /> _ <br /> ' Detailed Room Loads - Room 7 - 2nd Story Owners Suite (Average Load <br /> Procedure) <br /> General <br /> Calculation Mode: Htg. &clg. Occurrences: 1 <br /> Room Length: 10.0 ft. System Number: 1 <br /> Room Width: 16.0 ft. Zone Number: 1 <br /> Area: 160.0 sq.ft. Supply Air: 107 CFM <br /> Ceiling Height: 8.0 ft. Supply Air Changes: 5.0 AC/hr <br /> Volume: 1,280.0 cu.ft. Req. Vent. Clg: 0 CFM <br /> Number of Registers: 1 Actual Winter Vent.: 14 CFM <br /> Runout Air: 107 CFM Percent of Supply.: 13 % I <br /> Runout Duct Size: 6 in. Actual Summer Vent.: 18 CFM I <br /> Runout Air Velocity: 544 ft./min. Percent of Supply: 17 % , <br /> , Runout Air Velocity: 544 ft./min. Actual Winter Infil.: 12 CFM ; <br /> Actual Loss: 0.185 in.wg./100 ft. Actual Summer Infil.: 6 CFM � <br /> Item Area -U- Htg Sen Clg Lat Sen ' <br /> Description Quantit�. Value HTM Loss HTM Gain Gain <br /> ! S-Wall-12F-Osw 10 X 8 55 0.065 5.3 290 1.1 0 58 '', <br /> � W-Wall-12F-Osw 16 X 8 92.6 0.065 5.3 487 1.1 0 98 i <br /> ' N -Wall-12F-Osw 10 X 8 80 0.065 5.3 421 1.1 0 85 � <br /> �, S-Gls-1 F-hw-o shgc-0.3 0%S 25 0.440 35.6 891 20.7 0 517 <br /> �i W-Gls-1 F-hw-o shgc-0.3 0%S (2) 20.8 0.440 35.6 742 35.0 0 730 ', <br /> W-Gls-1 F-hw-o shgc-0.3 0%S 14.6 0.440 35.6 520 35.1 0 512 ' <br /> UP-Ceil-16B-50 10 X 16 160 0.020 1.6 259 1.0 0 163 <br /> ' Subtotals for Structure: 3,610 0 2,163 <br /> Infil.: Win.: 11.6, Sum.: 6.2 288 3.483 1,003 0.368 123 106 ' <br /> AED Excursion;_ ______ _ 9 , <br /> __ _ _ -_ � <br /> � Room Totals: 4,613 123 2,278 ' <br /> C:\...\Kindl Residence.rh9 Thursday, September 29, 2016, 12:18 PM <br />